Page 1: ...mp Oral Rectal Under the Arm Not for use as an Ear Thermometer Model 18 500 000 Please read this detailed guidebook completely before operating this unit English French Portuguese Spanish For hygienic purposes and to ensure accuracy RapidTemp must be used with probe covers ...

Page 2: ...mpleted and sent to us within 10 days of the pur chase date This Limited Warranty constitutes MABIS Healthcare s only responsibility and obligation to repair and or replace materials or components We make no other express or implied warranties arising by operation of law or otherwise or any warranty of merchantability or fitness for a particular use or purpose whether or not the use or purpose has...

Page 3: ...urchasing an MABIS RapidTemp Thermometer Please read the following instructions to achieve the most accurate temperatures and safe opera tion With proper care and use your thermometer will provide you with many years of reliable readings Your thermometer is intended for monitoring human body temperature in the home and is appropriate for all ages It can be used orally rectally or under the arm Rea...

Page 4: ...n body temperature measurement Only use under the supervision of an adult Never leave the thermometer or probe covers with unattended infants or children Do not use if there are signs of damage to the thermometer Do not attempt to disassemble it except to replace the battery Protect the thermometer from severe impact Probe tip Digital display POWER button MODE button Battery cover 4 ...

Page 5: ...ash with COLD soapy water DO NOT submerse in any solution or let water penetrate the thermometer The unit is not waterproof water resistant Apply a disposable probe cover to the tip of a clean dry ther mometer Changing Selecting Modes Your unit has 4 modes 1 Oral 2 Axillary under the arm 3 Rectal 4 All Purpose Note Default is set at Oral the head will flash upon first turning the unit on 5 ...

Page 6: ...own below Press the MODE button to scroll through the four Modes Oral Axillary Rectal and All Purpose Press the POWER button to set the appropriate Mode Thermometer will beep and display as shown example of Oral Mode The thermometer is ready to take a measurement Oral Mode 1 Place the probe tip under the tongue near the heat pockets shown on the diagram Fig 1 Diagram illustrates heat pockets and t...

Page 7: ...method should only be used when it is impossible or impractical to take an oral or axillary temperature 1 After applying a disposable probe cover apply a water soluble lubricant to the tip Do not use petroleum jelly 2 Gently insert the probe a MAXIMUM of 1 2 into the rec tum DO NOT force insertion if there is any detected resistance 3 In approximately 6 seconds peak temperature will be reached and...

Page 8: ...ed on Temperature in Fahrenheit scale Fahrenheit Fast Measuring Mode Oral Fast Measuring Mode Axillary Fast Measuring Mode Rectal Standard Measuring Mode All Purpose System waiting 8 Description of Display Symbols ...

Page 9: ...too low Ambient temperature out of measuring range too high Accurate reading cannot be obtained Interruption during Fast Measuring Mode Operating temperature is higher than 104 0o F 40 0o C The operating temperature check only operates when power is on If this error message appears when the POWER button is pressed the thermometer will automatically power off Description of Display Symbols 9 ...

Page 10: ... unit Fig 2 2 Slide the battery cover off located on the front of the unit Fig 3 3 Using a non metal pointed tool carefully remove the battery and insert the new battery with the positive side facing upward Fig 4 4 Carefully reattach and slide the battery cap back into place 5 Replace the screw making sure the cover is attached Please properly dispose the battery away from small children and heat ...

Page 11: ...perature as described above Standard mode 0 2o F 0 1o C Fever alarm A bell symbol displays when reading is above the following temperatures Instant mode Oral Mode 100 0o F 37 8o C Axillary Mode 99 3o F 37 4o C Rectal Mode 100 4o F 38 0o C Standard mode N A Automatic power off Automatic shut off after approximately 2 minutes of nonuse Battery 1 each CR2032 battery Dimensions 6 1 8 L x 1 3 8 W x 3 4...