Voltage  automatic  compensation  circuit  will  prevent  from  exceeding  allowable 

arrange .If power voltage is too high, that will damaged to components. User must 

be carefully. 

4.

 

There  is  a  grounding  screw,  which  is  marked  grounding  behind  cutting  machine. 

Make  sure  the  mantle  is  grounded  reliably  by  cable  whose  section  is  6  square 

millimeter in order to prevent from leaking electrify and bringing electrostatic. 

5.    Inter  heat-variable  component  is  starting  if  machine  is  exceeded  in  duty  cycles. 

That  will  cause-cutting  machine  will  stop  working  suddenly  and  inter  red diode  is 

lit.  User  need  not  break  the  circuit  and  the  fan  may  continue  working  in  order  to 

cool down the machine. Once temperature is reduced to allowable arrange, machine 

can be operated again.

 

CUTTING NOTES   

1.

 

Make sure copper tip must not connect to work piece directly when user is cutting. 

Torch should be inclined and it is 1 mm from inter-hole of copper tip to work piece 

in order to protect copper tip. 

2.

 

As  arc-supporting  cutting  machine, if  arc-supporting  frequency  is  down or  there  is 

no arc supporting, user may be get rid of oxidized film of inter electrode by abrasive 

paper. Then machine will be operated normally. 

 

MAINTENANCE AND CHECK TROUBLE 

Maintenance 

1.

 

Remove  dust  by  compressed  air  regularly  .If  cutting  machine  is  placed  in 

environment where condition is polluted with smoke and dust, cutting machine must 

be removed dust every day. 

2.

 

Pressure is adequate to cutting in order to protect little components. 

3.

 

Check  the  electrify  connectors  and  make  sure  the  connectors  are  connected  firmly 

(specially connect and insert components), tighten the connectors 

4.

 

Avoid water into machine and machine become damp, or the machine must be dried 

in  time  and  measured  insulation  by  meter.  After  there  is  no  problem,  the  machine 

Summary of Contents for CUT 40

Page 1: ...PLASMA CUTTER OWNER S MANUAL MODEL CUT 40 60 POWER v MOS CONTROLIED PLASMA CUTTING POWER SUPPLY ...

Page 2: ...wer is used volume and weight of main transformer has reduced substantially and efficiency has been increased by 30 Piloting arc system can strike arc easily with principle of high frequency oscillation It has functions that it can supply gas ahead and turn off gas delayed cutting machine has characteristics as following 1 Stabilizing 2 Reliability 3 Lightness 4 Energy saving and no noise 5 High c...

Page 3: ...e phase 220V 15 Three phase 380V 15 Rated input power KVA 6 6 7 9 No load voltage v 230 295 Rated input current A 30 12 Rated output voltage v 96 104 Duty cycle 60 60 Pilot arc model HF oscillating HF oscillating Burner inter diameter mm 1 0 1 2 Pressure of air compressor kg 4 5 4 5 Thickness mm 1 12 1 20 Weight kg 9 19 Dimensions mm 371 153 232 480 204 303 ...

Page 4: ...YF 22 A2 3 The panel picture above is for reference only If any difference with the real machine please follow with the real machine INSTALLATION ...

Page 5: ...n 4 Get down the plastic screw and fix the regulator on the shelf 5 Turn on the air valve turn up the pressure adjusting knob Turn the pressure to rated volume meter inside shows KG and then put down the knob means increasing pressure means decreasing pressure 6 Scale of the meter is as follow The volume in the picture is 6 kg 7 If the water in the gas filtering bottle is too much please turn on t...

Page 6: ...obile plug of another end of earth cable is connected to positive terminal of front panel then tighten it 3 Make sure air plug of torch is connected to switch connector of panel If it is pilote arc cutter pilote arc cable of torch is connected to terminal of pilote arc wiring column CHECK 1 Check if cutting machine is grounded reliably according to standard 2 Check if all connectors are connected ...

Page 7: ... dust or corrosive gas in the air SAFTY 1 Make sure the working area is adequately ventilated Cutting machine is light and its structure is compact and the electromagnetic fields generated the high current So natural wind is not satisfy to cool down components there are two axial flow fan in inter machine in order to force to cool down it NOTES Exhaust shutter must not in block or covered it is 0 ...

Page 8: ... tip must not connect to work piece directly when user is cutting Torch should be inclined and it is 1 mm from inter hole of copper tip to work piece in order to protect copper tip 2 As arc supporting cutting machine if arc supporting frequency is down or there is no arc supporting user may be get rid of oxidized film of inter electrode by abrasive paper Then machine will be operated normally MAIN...

Page 9: ...and fan is working However press control knob of torch there is no HF arc striking sound and inter red diode is lit 1 Check if MOS K1170 of top board is damaged driver mould is damaged 2 Rising transformer of bottom board is damaged 3 Control mould is damaged 4 Switch indicator is lit and fan and electromagnetic valve are working However there is no sound of HF arc striking and inter red diode is ...

Page 10: ...here is no DC 24V output 3 Open the air switch fan and indicator are working Press knob of torch electromagnetic valve is starting there is no sound of HF arc striking and red diode is not lit There is some fault in part of arc striking such as 1 It is too far between discharge tip or there is adhesion in discharge tip 2 Primary coil of arc striking transformer is damaged or poor contact 3 Check i...