Check Fault   

 
 
 

CUT 40 

 
 

Faults 

Resolvable Methods 

1.

 

Switch indicator is on, fan is not working 

      and control knob is out of work.   

1.

 

Over voltage protection is working. Close machine then 

Open it again after several minutes.   

2.

 

Switch indicator is lit and fan is working. 

      However, press control knob of torch, there 

      is no HF arc-striking sound and 

      electromagnetic valve is not working.   

1.

 

Check if torch is open circuit. 

2.

 

Check if control knob of torch is damaged. 

3.

 

Part  of  assistant  power  of  top  board  is  damaged  and  there 

is no DC 24V output.   

3.    Switch indicator is lit and fan is working. 

      However, press control knob of torch, there 

      is no HF arc striking sound and inter red 

      diode is lit.   

1.

 

Check  if  MOS  K1170  of  top  board  is  damaged  (driver 

mould is damaged). 

2.

 

Rising transformer of bottom board is damaged. 

3.

 

Control mould is damaged.   

4.

 

Switch indicator is lit and fan and 

      electromagnetic valve are working. 

      However, there is no sound of HF 

      arc-striking and inter red diode is not lit. 

 

There is some trouble in part of arc-striking, such as: 

1.

 

It  is  too  far  between  discharge  tip  or  there  is  adhesion  in 

discharge tip. 

2.

 

Primary  coil  of  arc-striking  transformer  is  damaged  or 

poor contact. 

3.

 

Check if four times voltage rectifier diode is stricken. 

4.

 

Check if HF electric capacity 102/10KV is leaking. 

Relay is damaged.   

5.

 

Other of machine is normal, but arc is not 

      be    stricken when it is be operating.     

1.

 

Input voltage is too low. 

2.

 

Pressure of air compressor is too high or too low . 

 
 

Summary of Contents for CUT 40

Page 1: ...PLASMA CUTTER OWNER S MANUAL MODEL CUT 40 60 POWER v MOS CONTROLIED PLASMA CUTTING POWER SUPPLY ...

Page 2: ...wer is used volume and weight of main transformer has reduced substantially and efficiency has been increased by 30 Piloting arc system can strike arc easily with principle of high frequency oscillation It has functions that it can supply gas ahead and turn off gas delayed cutting machine has characteristics as following 1 Stabilizing 2 Reliability 3 Lightness 4 Energy saving and no noise 5 High c...

Page 3: ...e phase 220V 15 Three phase 380V 15 Rated input power KVA 6 6 7 9 No load voltage v 230 295 Rated input current A 30 12 Rated output voltage v 96 104 Duty cycle 60 60 Pilot arc model HF oscillating HF oscillating Burner inter diameter mm 1 0 1 2 Pressure of air compressor kg 4 5 4 5 Thickness mm 1 12 1 20 Weight kg 9 19 Dimensions mm 371 153 232 480 204 303 ...

Page 4: ...YF 22 A2 3 The panel picture above is for reference only If any difference with the real machine please follow with the real machine INSTALLATION ...

Page 5: ...n 4 Get down the plastic screw and fix the regulator on the shelf 5 Turn on the air valve turn up the pressure adjusting knob Turn the pressure to rated volume meter inside shows KG and then put down the knob means increasing pressure means decreasing pressure 6 Scale of the meter is as follow The volume in the picture is 6 kg 7 If the water in the gas filtering bottle is too much please turn on t...

Page 6: ...obile plug of another end of earth cable is connected to positive terminal of front panel then tighten it 3 Make sure air plug of torch is connected to switch connector of panel If it is pilote arc cutter pilote arc cable of torch is connected to terminal of pilote arc wiring column CHECK 1 Check if cutting machine is grounded reliably according to standard 2 Check if all connectors are connected ...

Page 7: ... dust or corrosive gas in the air SAFTY 1 Make sure the working area is adequately ventilated Cutting machine is light and its structure is compact and the electromagnetic fields generated the high current So natural wind is not satisfy to cool down components there are two axial flow fan in inter machine in order to force to cool down it NOTES Exhaust shutter must not in block or covered it is 0 ...

Page 8: ... tip must not connect to work piece directly when user is cutting Torch should be inclined and it is 1 mm from inter hole of copper tip to work piece in order to protect copper tip 2 As arc supporting cutting machine if arc supporting frequency is down or there is no arc supporting user may be get rid of oxidized film of inter electrode by abrasive paper Then machine will be operated normally MAIN...

Page 9: ...and fan is working However press control knob of torch there is no HF arc striking sound and inter red diode is lit 1 Check if MOS K1170 of top board is damaged driver mould is damaged 2 Rising transformer of bottom board is damaged 3 Control mould is damaged 4 Switch indicator is lit and fan and electromagnetic valve are working However there is no sound of HF arc striking and inter red diode is ...

Page 10: ...here is no DC 24V output 3 Open the air switch fan and indicator are working Press knob of torch electromagnetic valve is starting there is no sound of HF arc striking and red diode is not lit There is some fault in part of arc striking such as 1 It is too far between discharge tip or there is adhesion in discharge tip 2 Primary coil of arc striking transformer is damaged or poor contact 3 Check i...

Reviews: