WARNING!
Depending on the actual use of the product the vibration values
can differ from the declared total. Adopt proper measures to protect yourself
against vibration exposures. Take the whole work process including times
the product is running under no load or switched off into consideration!
Proper measures include among others regular maintenance and care of
the product and accessories, keeping hands warm, periodical breaks and
proper planning of work processes!
Unpacking
NOTE:
The product is heavy, ask another person for assistance if
required.
1.
2. Remove all packing materials and protective shipping materials, if applicable.
3.
that parts are missing or show damage do not use the product and contact your
dealer. Using an incomplete or damaged product represents a hazard to operators
and property.
4. Ensure that you have all the accessories and tools needed for assembly and
operation. This also includes suitable personal protective equipment.
WARNING!
The product and the packaging are not children’s toys! Children
must not play with plastic bags, sheets and small parts! There is a danger
of choking and suffocation!
>
Nominal power:
2.1 kW
>
Spark plug type:
XC92YC
>
Spark plug gap:
0.7-0.8 mm
Battery
>
Battery voltage:
10.8 V
>
Battery type:
Li-ion
>
Battery capacity:
2000 mAh
Charger
>
Model number:
EBVA+07013-0500
>
Rated input voltage/frequency:
100-240 V, 50/60 Hz
>
Rated input current:
0.2 A
>
Rated output voltage:
13 V
>
Rated output current:
0.5 A
>
Protection class:
II
>
Charging time:
5 h
Sound level
>
Sound pressure level at operator’s position
L
pA
:
80.6 dB(A)
>
Uncertainty K:
3 dB(A)
>
Sound power level L
WA
:
92.5 dB(A)
>
Uncertainty K:
1.87 dB(A)
>
Guaranteed sound power level L
WA
(acc. to 2000/14/EC amended by 2005/88/EC):
96 dB(A)
Vibration level
>
Hand-arm vibration a
hw
:
3.94 m/s
2
>
Uncertainty K:
1.5 m/s
2
The sound values have been determined according to noise test code given in
EN ISO 5395-1 and EN ISO 5395-2, using the basic standards ISO 3744 and ISO 11094.
Wear hearing protection, especially when sound pressure is over 80 dB(A).
The declared vibration value has been measured in accordance with a standard
test method (according to EN ISO 5395-1 and EN ISO 5395-2) and may be used for
comparing one product with another. The declared vibration value may also be used
to evaluate the exposure for the user caused by vibration in advance.
Your product
Your product / Before you start