background image

OM-154 500 Page 10

B. Motor Fuse F1

CAUTION

STATIC ELECTRICITY can damage parts on circuit boards.

Put on grounded wrist strap BEFORE handling boards or parts.

fwarn5.1* 9/91

Turn Off and unplug unit. Unlatch
door, and remove door/wrapper.

1

Motor Control Board PC1

2

Fuse F1 (See Parts List For
Rating)

If F1 opens, wire does not feed.

Pull fuse from fuse holder on PC1.
To reinstall, push fuse into fuse
holder.

Reinstall wrapper, and latch door.

Ref. ST-150 194-B / ST-149 921-A

1

2

Figure 4-1. Fuse F1 Location

4-3.

Drive Assembly Maintenance

READ SAFETY BLOCKS at start of
Section 4 before proceeding.

WARNING

Turn Off and unplug unit.

1

Wire Spool

2

Gun Contact Tube

Cut welding wire off at contact tube.
Retract wire onto spool and secure.

3

Pressure Roll Arm

4

Cotter Pin

5

Pin

6

Screw

7

Bearing

Remove bearing as shown. Install
new bearing and secure with screw.
Reinstall arm onto pin and secure
with cotter pin.

8

Screw

9

Drive Roll

Remove drive roll as shown.

Use a wire brush to clean drive roll.
Push drive roll onto shaft and rein-
stall screw and washers.

10 Wire Inlet Guide

Remove guide by pressing on
barbed area or cutting off one end
near housing and pulling it out of
hole. Push new guide into hole from
rear until it snaps in place.

Thread welding wire (see Section
2-6). Close door.

Ref. ST-150 193-C / ST-155 578

3

4

5

6

7

9

8

10

10

1

Tools Needed:

2

Figure 4-2. Drive Assembly Maintenance

Summary of Contents for MW150K

Page 1: ...carefully Have only trained and qualified persons install operate or service this unit Call your distributor if you do not understand the directions Give this manual to the operator For help call you...

Page 2: ...undersized or poorly spliced cables 8 Do not wrap cables around your body 9 Ground the workpiece to a good electrical earth ground 10 Do not touch electrode while in contact with the work ground circu...

Page 3: ...de to touch any cylinder 5 Use only correct shielding gas cylinders regulators hoses and fittings designed for the specific application maintain them and associated parts in good condition 6 Turn face...

Page 4: ...Gun Rated Output Air Cooled 160 Amperes At 60 Duty Cycle Using CO2 Shielding Gas Cable Length 10 ft 3 m 1 1 Volt Ampere Curve And Duty Cycle Chart CAUTION USING GUN BEYOND DUTY CYCLE RATING can damage...

Page 5: ...e in bracket and chain 3 Chain 4 Snap Crimp onto open end of chain 5 Cylinder Bracket For Large Gas Cylinder 6 Gas Fitting ST 160 791 1 2 3 Tools Needed 4 5 6 Figure 2 2 Installing Safety Chain B Inst...

Page 6: ...door Ref ST 149 629 B 2 4 1 3 Figure 2 5 Gun Connections 2 5 Connecting Input Power Table 2 1 Electrical Service Requirements Input Voltage 230 Input Amperes At Rated Output 20 Recommended Standard F...

Page 7: ...tacle 4 Input Conductors 5 Grounding Conductor Select size and length using Table 2 1 Conductor rating must comply with national state and lo cal electrical codes Install and connect input conduc tors...

Page 8: ...e Spool 2 Hub Tension Nut Grasp spool in one hand and turn while using a wrench to adjust nut When a slight force is needed to turn spool tension is set Loosen wire from spool and cut off bent wire an...

Page 9: ...oltage Adjustment switch position while welding Arcing inside switch can damage contacts causing switch to fail READ SAFETY BLOCKS at beginning of manual before proceeding WARNING 1 1 Insulating Glove...

Page 10: ...oltage Adjustment Switch Use switch to select an arc voltage The higher the selected number the thicker the material that can be welded see Table 3 1 3 Power Switch Use switch to turn unit On and Off...

Page 11: ...80 3 60 3 50 3 90 3 70 3 60 2 45 2 40 3 90 3 65 3 50 3 80 3 85 2 2 1 1 1 70 60 55 45 35 2 2 1 1 60 50 40 30 2 1 1 1 40 30 20 15 2 2 1 1 1 80 70 60 50 40 2 2 1 1 60 50 30 45 2 2 1 3 50 40 33 25 1 1 1...

Page 12: ...r Clean and check wire drive parts replace as necessary Every 3 months Tape or replace cracked cables clean and tighten connections Replace unreadable labels Every 6 months Blow out or vacuum inside o...

Page 13: ...ARNING Turn Off and unplug unit 1 Wire Spool 2 Gun Contact Tube Cut welding wire off at contact tube Retract wire onto spool and secure 3 Pressure Roll Arm 4 Cotter Pin 5 Pin 6 Screw 7 Bearing Remove...

Page 14: ...ut liner off Reinstall gun so that liner is as close as possible to drive rolls without touch ing Thread welding wire see Section 2 6 Close door Ref ST 149 629 C Ref ST 155 509 Tools Needed 3 8 in 3 2...

Page 15: ...nlet guide or liner if dirty or plugged 4 3 4 4 Replace drive roll or pressure bearing if worn or slipping 4 3 Secure gun trigger plug in receptacle or repair leads or replace trig ger switch 2 4 Chec...

Page 16: ...OM 154 500 Page 13 Figure 5 2 Wiring Diagram For Welding Power Source SC 163 085...

Page 17: ...RTS LIST ST 155 497 B Figure 6 1 Main Assembly 1 2 3 4 5 6 7 18 9 10 11 12 13 14 20 21 22 23 24 8 15 16 17 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 26 27 49 50 51 52 53...

Page 18: ...572 Bracket 52 Rear Panel w Cmpts 128 751 Gas Valve 605 227 Nyl Nut gas valve 152 118 Cord Set 111 443 Bushing cord set 147 443 Rear Panel 146 619 Bezel 147 548 Speed Nut 156 339 Bottle Retainer 602 3...

Page 19: ...Notes...

Page 20: ......

Reviews: