OM-154 501 Page 5
SECTION 2
−
SPECIFICATIONS
2-1. SPECIFICATIONS
Specifications
Description
Type Of Output
Direct Current/Constant Voltage (DC/CV)
Rated Weld Output
200 Amperes, 28 Volts DC, 60% Duty Cycle (See Section 2-2)
Type Of Input Power
Single-Phase; 60 Hz; At 200 Or 230 Volts AC
Input Amperes At Rated Output
46 A At 200 V, 40 A At 230 V
Maximum Input Amperes While Idling
1.2 A At 200 V, 1 A At 230 V
KVA/KW Used At Rated Output
9.5 kVA/8.3 kW
Maximum KVA/KW Used While Idling
0.24 kVA/0.17 kW
Max. Open-Circuit Voltage
42 Volts DC
Control Circuit Voltage At Gun
24 Volts DC
Welding Processes
Gas Metal Arc (GMAW) And Flux Cored Arc Welding (FCAW)
Calculated Speed Range At No Load
128 To 1051 ipm (3.2 To 266.9 mpm)
Wire Diameter Range
.030 To .045 in (0.8 To 1.1 mm) Flux Cored Wire, .023 To .045 in (0.6 To 1.1 mm) Hard Wire
Overall Dimensions
Length: 37 in (940 mm); Width: 19 in (483 mm); Height: 30-1/4 in (768 mm)
Weight
Net: 225 lb (102 kg); Ship: 271 lb (123 kg)
Welding Gun
Rated Output (Air Cooled)
200 Amperes At 60% Duty Cycle Using CO
2
Shielding Gas (See Section 2-2)
Cable Length
15 ft (4.5 m)
2-1. Volt-Ampere Curves
Volt-ampere curves show mini-
mum and maximum voltage and
amperage output capabilities of
unit. Curves of other settings fall be-
tween curves shown.
va_curve1
−
4/95
−
SB-049 424-D