background image

08

Fix the spring housing to the loft floor with 4 x

20mm screws (F3) through the 4 inner holes. 

Place the housing cover (F2) over the spring

housing and fix down using 2 x 20mm (F3) screws

through the 2 remaining outer holes. 

8.5

8.4

8.3

Installing the Power Pivot System

8.1

B3

B1

B2

If flooring material covers the top edge of the loft hatch frame ensure that it is completely stable and if necessary

use longer screws to penetrate the frame itself. 
The ladder should now be free to swing from the hinges and slide freely up and down the guides. 

Installing the Ladder

N.B.

The ladder should be installed on the same side

of the trap as the trapdoor hinges.

With the ladder preferably centred in the

opening, and the trapdoor hanging down, locate the

hinge guide bracket arms (B1 & B2) on the top edge

of the loft hatch frame (see diagram).

Make guide holes with the bradawl then pre

drill pilot holes (2mm diameter) for all screws. 

Fix using 35mm screws (B3). 

N.B.

the bracket arms with two screw holes should be

on top.

7.3

7.2

7.1

Installation 

and 

operating 

instructions

8.5

8.4

8.3

B3

B1

B2

Installing the Ladder

.

of the trap as the trapdoor hinges.

s

7.3

7.2

7.1

Using a bradawl mark the 6 fixing positions on to 

the loft floor through the 6 applicable holes in the spring 

housing (F1).

Decide which side of the ladder the power pivot 

assembly will be fitted (left-hand or right-hand side) then 

follow relevant instructions below marking the lines in the 

directions as illustrated:
RIGHT HAND SIDE: Measure 28mm from inside (LH) face 

of the right-hand hinge-guide bracket & mark a line 

655mm long on the loft floor at 90° from the edge of the 

opening. Next measure 435mm along the line you have 

just marked from the loft opening & mark a new line 

100mm across on the loft floor at 90°to the first line.
LEFT HAND SIDE: Measure 64mm from inside (RH) face of the left-hand hinge-guide bracket & mark a line 

655mm long on the loft floor at 90° from the edge of the opening. Next measure 435mm along the line you have 

just marked from the loft opening & mark a new line 100mm across on the loft floor at 90° to the first line.

 Position the spring housing (F1) by following the relevant instructions below for the side of the ladder that 

you have selected to fit the power pivot system:
RIGHT HAND SIDE:

 

Place the spring housing (F1) so the front left-hand corner is positioned where the two lines 

that have been marked intersect. So the front face is positioned on the horizontal line you have marked on the loft 

floor and the left-hand face is positioned on the vertical line marked on the loft floor. Ensure the arm points AWAY 

from the loft opening (with slot in cover on the left-hand side).
LEFT HAND SIDE: Place the spring housing (F1) so the front right-hand corner is positioned where the two lines 

that have been marked intersect. so the front face is positioned on the horizontal line you have marked on the loft 

floor and the right-hand face is positioned on the vertical line marked on the loft floor. Ensure the arm points AWAY 

from the loft opening (with slot in cover on the left-hand side).

8.2

F2

F3

F1

F3

F3

F2

F3

F1

F3

F3

For Right

Hand Fixing

For Left

Hand Fixing

100mm

100mm

435mm

655mm

435mm

655mm

435mm

655mm

435mm

655mm

WARNING:

Do Not stand on the ladder to do this. Either using a

second ladder, or from inside the loft space, secure

the hinges using six 35mm screws supplied.

64mm

28mm

LEFT HAND

FIXING EXAMPLE

Summary of Contents for 3663602910626

Page 1: ...LE ENCOMBREMENT 3 PLANS LF37093 Rev B 12 19 WARNING Please read the instructions before using the loft ladder AVERTISSEMENT Lisez les consignes avant d utiliser l chelle EN FR FR EN LL6A EAN 366360291...

Page 2: ...LF37093 MacAllister indd 2 28 04 2016 14 52 LF37 LF37093 MacAllister 1219_PRINT 2 11 12 2019 14 18...

Page 3: ...on and operating instructions 05 FR Commen ons Ces instructions sont pour r alis es votre s curit Nous vous remercions de prendre le temps de les lire attentivement avant l utilisation du produit Cons...

Page 4: ...nt vers le bas jusqu atteindre les but es sup rieures des deux c t s pour l utilisation Ensure both feet of the ladder are in contact with a firm and level surface Assurez vous que votre chelle repose...

Page 5: ...ise off any support battens Tape measure Ruler Hammer D E A B F 14 52 03 Safety instructions Tools required Stowed Requirements Deployed Requirements 68 80 At handrail low position 710mm 28 At handrai...

Page 6: ...A7 B1 G3 G7 CSK Please check you have all components listed tick boxes 28 04 2016 14 52 Tools required Stowed Requirements Deployed Requirements 68 80 At handrail low position 710mm 28 At handrail to...

Page 7: ...s Chipboard and MDF may not be suitable 1 1 14 52 05 Installation and operating instructions Adapting the trapdoor The loft ladder is suitable for a loft opening flush with the ceiling having a hinged...

Page 8: ...e REAR frame of the ladder noting which way round they go 4 1 A1 A4 A7 A3 A2 A3 A2 45 28 04 2016 14 52 Fixing the Location Bracket When turned to the correct position the catch lever will engage in th...

Page 9: ...6 4 6 3 D1 D2 Right side Left side 150 mm 14 52 07 Installation and operating instructions B1 B2 Slide the hinge guides B1 B2 onto the rear frame stiles The brackets should be positioned outwards with...

Page 10: ...at 90 from the edge of the opening Next measure 435mm along the line you have just marked from the loft opening mark a new line 100mm across on the loft floor at 90 to the first line LEFT HAND SIDE Me...

Page 11: ...n side of the rear frame Use 3 x spacers E1 60mm bolts E2 washers and nuts E3 E4 supplied You have a choice of 2 different handrail heights which will be dependent on the amount of in loft handrail yo...

Page 12: ...tep 11 1 and ensure both right hand side catches C and D blue are fully engaged 11 4 28 04 2016 14 52 G2 G3 Additional Top stops Fitted No Additional Top stops Fitted B A Stowing the Ladder Retract bo...

Page 13: ...it normales lors du travail dans le grenier Positionnez le poids exclusivement sur les solives porteuses du plafond Ne percez pas plus haut que votre t te vitez tout contact avec des fils lectriques V...

Page 14: ...75 153 0 6 438 0 17 25 178 0 7 450 0 17 75 203 0 8 463 0 18 25 D E A B F 28 04 2016 14 52 IMPORTANT N ESSAYEZ PAS de monter sur votre escalier escamotable tant qu il n a pas t compl tement install qu...

Page 15: ...nce Les pi ces requises sont fournies 14 52 13 FR Instructions d installation et d utilisation Adapter la trappe Installer la trappe G5 26 mm 1 au minimum 1 2 1 3 1 4 1 5 1 6 1 7 A1 A2 A4 A3 2 1 2 2 2...

Page 16: ...embouts en plastique du bas du plan ARRI RE de l chelle en notant leur sens d insertion 28 04 2016 14 52 3 4 paisseur de la trappe paisseur de la trappe 9 mm paisseur de la trappe 9 mm A6 A5 3 3 3 1...

Page 17: ...mont s et fixez les avec les goujons 14 52 15 FR Instructions d installation et d utilisation B1 B2 4 2 C1 C2 C3 But e sup rieure permanente 4 3 4 4 Hauteurs d utilisation des 3 sections Millim tres...

Page 18: ...es Puis assemblez l extr mit de rotation F4 Instructions d installation et d utilisation 28 04 2016 14 52 F4 8 8 8 7 8 6 F2 F3 F1 F3 F3 8 5 8 4 8 3 8 2 8 1 Fixation droite Fixation gauche B3 B1 B2 7 3...

Page 19: ...une utilisation fluide de l escalier 14 52 FR 17 E2 E1 E2 E1 G6 F5 F8 F7 F6 F4 F6 9 3 9 2 9 1 8 10 8 9 G3 A1 1 1 1 2 2 2 G6 E1 E2 E2 E1 E3 E4 10 2 10 1 Fixer la main courante La main courante G6 peut...

Page 20: ...ts de blocage sont compl tement verrouill s Instructions d installation et d utilisation 28 04 2016 14 52 G2 G3 But es sup rieures additionnelles assembl es Pas de but es sup rieures additionnelles as...

Page 21: ...te x 1 G7 Vis autoforeuse x 1 14 52 IMPORTANT N ESSAYEZ PAS de monter sur votre escalier escamotable tant qu il n a pas t compl tement install qu il n a pas t abaiss jusqu aux but es sup rieures appro...

Page 22: ...LF37093 MacAllister 1219_PRINT 22 11 12 2019 14 19...

Page 23: ...LF37093 MacAllister 1219_PRINT 23 11 12 2019 14 19...

Page 24: ...products Distributor B Q Limited Chandlers Ford Hants SO53 3LE United Kingdom www diy com Screwfix Direct Limited Trade House Mead Avenue Yeovil BA22 8RT United Kingdom www screwfix com To view instru...

Reviews: