UNLOADING AND ASSEMBLY
169558
30
Revision D
NOTE
If one end of the header does
NOT
raise fully, the lift cylinders require
re-phasing, proceed as follows:
1. Press and hold the HEADER UP switch until
both cylinders stop moving.
2. Continue to hold the switch for three to four
seconds.
3. Cylinders are phased.
DANGER
To avoid bodily injury from fall of raised
header, always engage header lift cylinder
stops when working on or around raised
header, and before going under header for
any reason.
g. Cylinder stops are located on both header lift
cylinders on the windrower. Engage lift cylinder
stops on both lift cylinders as follows:
1. Stop engine, and remove key from ignition.
2. Pull lever (N), and rotate toward header to
release and lower cylinder stop (O) onto
cylinder.
3. Repeat for opposite lift cylinder.
h. Remove pin from storage location (P) in linkage,
and insert in hole (Q) to engage float springs.
Secure with lynch pin.
i. Disengage lift cylinder stop by moving lever (N)
downward to release, and lower stop until lever
locks into vertical position. Repeat for opposite
cylinder stop.
j. Start engine, and activate HEADER DOWN
switch on Ground Speed Lever (GSL) to lower
header fully. Stop engine, and remove key.
k. Connect header drive hydraulics (R) and
electrical harness (S) to header. Refer to your
auger header operator’s manual.
HEADER DOWN
HEADER UP
HEADER TILT UP
HEADER
TILT DOWN
R
S
P
Q
N
O