215981
123
Revision A
1023406
A
B
1
2
A
C
Figure 5.106: Knife Pressure Hose Positions
1 - Knife Pressure Hose in Storage Position
–
Rotary Configuration
2 - Hose to Knife Pressure Receptacle
–
Auger/Draper Configuration
7.
Quick couplers:
If switching from an auger/draper header
to a rotary header, disconnect hose (A) from knife pressure
receptacle (C) on the frame, and move it to storage
location (B).
E
A
C
1036604
B
D
F
Figure 5.107: Quick Couplers
8.
Quick couplers:
Connect the hydraulic hoses to a
windrower with quick coupler fittings as follows:
a.
Connect disc pressure hose (A) to coupler (B). Torque
the connection to 216 Nm (159 lbf·ft).
b.
Connect disc return hose (C) to coupler (D). Torque the
connection to 216 Nm (159 lbf·ft).
c.
Connect case drain hose (E) to fitting (F), with the relief
valve pointing towards the ground.
NOTE:
If necessary, loosen fitting (F) and retighten it to ensure that
the relief valve is pointing straight down.
d.
If connecting to a grass seed header, proceed to Step
. Otherwise proceed to Step