IMPORTANT:
• SCR System Cleaning inhibit (A) allows the Operator to temporarily prevent the machine from performing
an SCR System Cleaning. It should be used only when the environment is unsafe to allow high exhaust
temperatures (e.g., inside of a building).
• SCR System Cleaning Forced (B) will rarely require activation by the Operator. If required, the switch (icon) will
flash amber. If the SCR System Cleaning Forced switch (icon) begins to flash, park the windrower outside in a
safe environment for high exhaust temperatures. Place the ground speed lever (GSL) in N-Detent, throttle to idle,
and press and hold the SCR System Cleaning Forced switch (icon) for three seconds. The engine will then take
over throttle control. During the three-second interval, the fuel icon and gauge will be replaced with the following
red text, HOLD 3 SECONDS (C), and the red border will turn white. After which, the fuel gauge will return and
the white border will start blinking. The border will revert to solid red when the switch (icon) is released.
147764
65
Revision A