OPERATOR’S STATION
Form 169469/169470/169471
27
Revision C
5.10.3 CONTROLS
IMPORTANT
To distribute the oil throughout the
system, perform the following steps
whenever the machine is first started after
storage for more than one week:
a. Turn blower switch to the first position, turn
temperature control switch to maximum heating,
and A/C control to “OFF”.
b. Start engine and operate at low idle until engine
is warm.
c. Click A/C switch from "OFF" to "ON" for one
second, then back to "OFF" for 5 to 10 seconds.
Repeat this step ten times.
5.10.4 A/C COMPRESSOR PROTECTION
The compressor is protected from excessively
low and high pressures by two switches that
shut down the compressor to prevent damage to
the system.
•
The LOW pressure switch opens when the
pressure falls to 2-8 psi (14-55 kPa) and
shuts down the compressor. When the
pressure rises to 15-25 psi (103-172 kPa),
the switch closes and allows the compressor
to run.
•
The HIGH pressure switch opens and stops
the compressor when the pressure rises to
315-335 psi (2172-2310 kPa). When the
pressure falls to 220-280 psi (1517-1930
kPa), the switch closes and allows the
compressor to run.
If the air conditioning system is shut down by
either switch, locate the source of the problem
and correct it before operating the system.
5.11 INTERIOR LIGHTS
Two interior lights are installed in the cab
headliner. A low intensity LED light (A) is
located directly overhead to provide ambient
lighting if desired, and functions only when the
road/field light switch is on. An on-off switch is
located on the light.
The other interior light (B) is located on the
headliner switch panel and the push-on, push-off
button is located on the light.
A
B
OUTSIDE AIR SWITCH
Controls Air Source
FRESH AIR – Starts Booster Fan &
Filtered Outside Air Drawn Into Cab
RECIRCULATE – Stops Booster Fan &
Cab Air Is Recirculated.
AIR CONDITIONING SWITCH
Controls A/C System
OFF - A/C Does Not Operate.
ON - A/C Operates With Blower
Switch On.
TEMPERATURE CONTROL
Controls Cab Temperature
INCREASE – Clockwise
DECREASE - Counter-Clockwise
BLOWER SWITCH
Controls Blower Speed
OFF/LO/MEDIUM/HI
Summary of Contents for M205 2010
Page 1: ...M205 Self Propelled Windrower OPERATOR S MANUAL Revision C Part 169469 25...
Page 51: ...OPERATOR S STATION Form 169469 169470 169471 49 Revision C continued next page...
Page 95: ...HEADER OPERATION D SERIES Form 169469 169470 169471 93 Revision C continued next page...
Page 181: ...MAINTENANCE SERVICE Form 169469 169470 169471 179 Revision C 7 10 13 3 Fuse Box Decal...