262391
122
Revision A
1033221
A
B
C
Figure 4.73: Installing Quick Change Blade
4.
Remove hairpin clip (A).
5.
Remove pin (B).
6.
Remove change tool (C).
1026451
A
B
C
D
Figure 4.74: Change Tool and Gauge
7.
Remove gauge (A) on change tool (B).
NOTE:
Section (C) of the gauge is used to check the material
thickness of the retaining bolts; section (D) of the gauge is
used to check the outer radius of the quick change plate.
1026425
A
Figure 4.75: Checking Retaining Bolts
8.
Thoroughly clean the area around and between the
retaining bolts and the quick change plate.
9.
Remove the blade. For instructions, refer
.
10. Place gauge (A) over the retaining bolt and rotate 90°.
•
If it is
NOT
possible to slide the gauge over the retaining
bolt during the rotation, then the retaining bolt is still in
working order.
•
If it
IS
possible to slide the gauge over the retaining bolt
during rotation, then the retaining bolt must be
replaced immediately.