215585
123
Revision A
6.6
Discharge Shield
–
No Conditioner
Discharge shields control the distribution of unconditioned crop when no conditioner is installed.
•
If a conditioner is being installed, the discharge shield needs to be removed. For instructions, refer to
•
If a conditioner is being removed, the discharge shield needs to be installed. For instructions, refer to
6.6.1
Removing Discharge Shield
–
No Conditioner
Discharge shields may need to be removed for machine service, but a rotary disc pull-type without a conditioner should
NOT
be operated without the discharge shield.
%
$
Figure 6.34: Rotary Disc Pull-Type with Transport
1.
Raise the rotary disc pull-type fully and extend the center-
link to maximize the space between shield (A) and carrier
frame (B).
$
Figure 6.35: Lift Cylinder Lock-Out Valves
2.
Close lift cylinder lock-out valves (A) on both sides of the
rotary disc pull-type. Valve handles should be in the closed
position (90° angle to the hose).