the new channel.
NOTE: This channel uses the MACE Area/Velocity sensor in conjunction with the
Mannings equation. This equation is limited to a depth of half-full circular pipe.
When the pipe is more than half-full, the "
Flowrate (using trickle flow)
" channel will
revert to using the standard continuity equation Q = V x A.
Edit a "Flowrate (using trickle flow)" - channel type
MACE XCi User Manual - 195 -