14
OPERATING INSTRUCTIONS
Switching the air compressor on
The compressor will make a continuous loud noise when the tank is charging -
this is normal.
1.
Lift the red on/off switch located on
top of the pressure regulator.
•
The compressor will charge the
main tank to 8 bar (116 psi) then
switch off.
•
The compressor will restart
automatically whenever the
pressure in the main tank falls
below a certain level.
2.
Check the operation of the safety
valve, under pressure, daily by pulling
the ring as shown in figure 7. Air
should be released you pull the ring and stop when the ring is released.
•
If the valve does not operate as described, or if the valve is stuck, it must
be replaced by qualified service personnel before using the compressor.
WARNING!
Do not remove or attempt to adjust the safety valve.
3.
Select the pressure you need using
the pressure regulator. See figure 8.
4.
Open the outlet tap.
Figure 10
Figure 8
Figure 7
Pressure
regulator
Output pressure
gauge
Summary of Contents for airmaster TIGER 9/24
Page 1: ...1 TIGER 9 24 AIR COMPRESSOR OPERATION MAINTENANCE INSTRUCTIONS 1107...
Page 21: ...21 PARTS DIAGRAM...
Page 23: ...23...
Page 24: ...24...