5. For the Yaskawa drive, connect four E-stop cables to the E-10, E-11, E-20 and E-21 blocks as shown below.
Note: If you have an additional external E-stop, wire it in series with the control E-stop. You will need to connect your
external E-stop into the 24V block and the other side into the blank terminal block. Then connect the red wire from the
control E-stop into the blank terminal block as well. Finally, put the black wire from the control E-stop into the terminal
block labeled E-Stop.
1. Wire incoming power to the back panel into the top of the door switch. Be sure you are bringing in the
recommended voltage that is on the panel nameplate.
Wire Incoming Power