9.

 Power Sources — This Mackie product should be connected to a power 

supply only of the type described in these operation instructions or as marked 

on this Mackie product. 

10.

 Power Cord Protection — Power supply cords should be routed so 

that they are not likely to be walked upon or pinched by items placed upon 

or against them, paying particular attention to cords at plugs, convenience 

receptacles, and the point where they exit this Mackie product. 

11.

 Object and Liquid Entry — Care should be taken so that objects do not 

fall on, and liquids are not spilled into, this Mackie product.

12.

 Damage Requiring Service — This Mackie product should be serviced only 

by qualified service personnel when:

A.

 The power-supply cord or the plug has been damaged; or

B.

 Objects have fallen, or liquid has spilled into this Mackie product; or

C.

 This Mackie product has been exposed to rain; or

D.

 This Mackie product does not appear to operate normally or exhibits  

  a marked change in performance; or

E.

 This Mackie product has been dropped, or its chassis damaged.

13.

 Servicing — The user should not attempt to service this Mackie product 

beyond those means described in this operating manual. All other servicing 

should be referred to the Mackie Service Department.

14.

 To prevent electric shock, do not use this polarized plug with an extension 

cord, receptacle or other outlet unless the blades can be fully inserted to 

prevent blade exposure.

Pour prévenir les chocs électriques ne pas utiliser cette fiche polariseé avec un 

prolongateur, un prise de courant ou une autre sortie de courant, sauf si les 

lames peuvent être insérées à fond sans laisser aucune pariie à découvert.

15.

 Grounding or Polarization — Precautions should be taken so that the 

grounding or polarization means of this Mackie product is not defeated. 

16.

 Power Precaution — Unplug this Mackie product during lightning storms 

or when unused for long periods of time. Note that this Mackie product is not 

completely disconnected from the AC mains service when the power switch is in 

the OFF position.

17.

 This apparatus does not exceed the Class A/Class B (whichever is ap-

plicable) limits for radio noise emissions from digital apparatus as set out in the radio 

interference regulations of the Canadian Department of Communications.

ATTENTION —Le présent appareil numérique n’émet pas de bruits radioélec-

triques dépassant las limites applicables aux appareils numériques de class 

A/de class B (selon le cas) prescrites dans le règlement sur le brouillage 
radioélectrique édicté par les ministere des communications du Canada.

WARNING

 — To reduce the risk of fire or electric shock, 

do not expose this appliance to rain or moisture.

CAUTION    AVIS

RISK OF ELECTRIC 

SHOCK 

DO NOT OPEN

RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

NO USER-SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED PERSONNEL

ATTENTION: POUR EVITER LES RISQUES DE CHOC

ELECTRIQUE, NE PAS ENLEVER LE COUVERCLE.  AUCUN

ENTRETIEN DE PIECES INTERIEURES PAR L'USAGER.  CONFIER

L'ENTRETIEN AU PERSONNEL QUALIFIE.

AVIS: POUR EVITER LES RISQUES D'INCENDIE OU

D'ELECTROCUTION, N'EXPOSEZ PAS CET ARTICLE 

A LA PLUIE OU A L'HUMIDITE

   The lightning flash with arrowhead symbol within an equilateral 

triangle is intended to alert the user to the presence of uninsulated

"dangerous voltage" within the product's enclosure that may be 

of sufficient magnitude to constitute a risk of electric shock to persons.

   Le symbole éclair avec point de flèche à l'intérieur d'un triangle 

équilatéral est utilisé pour alerter l'utilisateur de la présence à 

l'intérieur du coffret de "voltage dangereux" non isolé d'ampleur 

suffisante pour constituer un risque d'éléctrocution.

   The exclamation point within an equilateral triangle is intended to 

alert the user of the presence of important operating and maintenance 

(servicing) instructions in the literature accompanying the appliance.

   Le point d'exclamation à l'intérieur d'un triangle équilatéral est 

employé pour alerter les utilisateurs de la présence d'instructions 

importantes pour le fonctionnement et l'entretien (service) dans le 

livret d'instruction accompagnant l'appareil.

SAFETY INSTRUCTIONS

1.

 Read Instructions — All the safety and operation instructions should be read 

before this Mackie product is operated.

2.

 Retain Instructions — The safety and operating instructions should be kept 

for future reference.

3.

 Heed Warnings — All warnings on this Mackie product and in these operating 

instructions should be followed.

4.

 Follow Instructions — All operating and other instructions should be 

followed.

5.

 Water and Moisture — This Mackie product should not be used near water 

– for example, near a bathtub, washbowl, kitchen sink, laundry tub, in a wet 

basement, near a swimming pool, swamp or salivating St. Bernard dog, etc.

6.

  Cleaning — Clean only with a dry cloth.

7.

  Ventilation — This Mackie product should be situated so that its 

location or position does not interfere with its proper ventilation. For 

example, the Component should not be situated on a bed, sofa, rug, or 

similar surface that may block any ventilation openings, or placed in a 

built-in installation such as a bookcase or cabinet that may impede the flow 

of air through ventilation openings.

8.

 Heat — This Mackie product should be situated away from heat sources 

such as radiators, or other devices which produce heat.

  

• Please write the serial number for your HRS120 here for 
 future reference (i.e., insurance claims, tech support, return 
authorization, etc.):

Purchased at:_______________________________  Date of Purchase:_________________

Summary of Contents for HRS120

Page 1: ...URE ARE REGISTERED TRADEMARKSOF MACKIE DESIGNS INC THX PM3 AND LUCASFILM ARE TRADEMARKS OF LUCASFILM LTD USED BY PERMISSION S M SLAVE MASTER SLAVE IN INPUT OUTPUT INPUT OUTPUT MASTER OUT LEFT IN OUT R...

Page 2: ...F ELECTRIC SHOCK DO NOT OPEN RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIF...

Page 3: ...nd HR624 meets all THX requirements for mixing and monitoring multi channel programs Inordertoachieveaseamlessintegrationbetween the subwoofer and the main speakers in the system speaker placement is...

Page 4: ...you really know what they do For now just leave all the switches out and the CROSSOVER controls set to the center position 80Hz For stereo applications 1 Connect the left and right line level signal...

Page 5: ...POWER ON POLARITY N A LFE GAIN SUBSONIC FILTER SUBSONIC FILTER CROSSOVER CONTROLS FILTER SELECT FILTER BYPASS STANDARD SETTINGS NORMAL 80Hz SUB SAT INPUT SENSITIVITY THX PM3 SETTINGS POLARITY LFE GAIN...

Page 6: ...netberaisedoffthegroundandatthesame level asyourears Ifthat snotpossible atleast putthe subwoofer in the same location as your listening position to achieve a close approximation PLACEMENT AN IMPORTAN...

Page 7: ...ubwoofer first and any other powered speakers in the system to prevent thumps and other noises generated by any upstream equipment from coming out the speakers When power ing up turn on the powered sp...

Page 8: ...SENSITIVITY control is in the NORMAL position Refer to the QUICK START section on page 4 for the level setting procedure This is where you connect your signal in puts and outputs to the subwoofer and...

Page 9: ...uthebestsound LEFT AND RIGHT INPUTS Balanced XLR female and unbalanced RCA female connectors are provided for the left and right inputs Connect the full range line level signal from the mixer or pream...

Page 10: ...ofer is bypassed An internal relay closes shorting the tip and sleeve of the REMOTE INDICA TOR jack whenever the subwoofer is in bypass mode either triggered manually with the FOOT SWITCH or by the au...

Page 11: ...SS FILTER IN FULL RANGE SUB 110Hz 55Hz 80Hz SAT CROSSOVER SUB 110Hz 55Hz 80Hz SAT MONO POWER POWER SUB BYPASSED DESIGNED BY MACKOIDS IN WOODINVILLE WA USA 2001 MACKIE DESIGNS INC ALL RIGHTS RESERVED P...

Page 12: ...ng You should use high quality shielded cable to connect the signal source to the LEFT and RIGHT IN and OUT jacks on the HRS120 Foil shielded cables such as Belden 8451 8761 or 9501 are commonly used...

Page 13: ...e hum Is there a light dimmer or other triac based SCR device on the same AC circuit as the monitor Dimmers cause buzzing noises Use an AC line filter or plug the subwoofer into a different AC circuit...

Page 14: ...e com click Support and select Locate a Service Center Service for Mackie products living outside the United States can be obtained through local dealers or distributors If you do not have access to o...

Page 15: ...SLAVE INPUT SUBWOOFER BYPASS FOOTSWITCH NOTE WHEN USED AS A SLAVE THE MASTER OUTPUT OF THE FIRST SUB DRIVES THIS INPUT POLARITY AND INPUT SENSITIVITY ONLY ARE ACTIVE ON THIS INPUT OPEN HPF FROM CROSSO...

Page 16: ...Thermal Protection Heatsink and Power Transformer temperature auto reset Amplifier Section Rated power output 1 THD 100 Hz 400 watts rms into rated 8 load Burst power output 100 Hz sine with 10 duty...

Page 17: ...Crossover Filter Response 40 10 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 2 4 6 8 dBr 20 20k 50 100 200 500 1k 2k 5k 10k Hz HRS120 Elliptical Filter Response 40 10 38 36 34 32 30 28 26 24...

Page 18: ...r of files A Hewlett Packard LaserJet 5000N with a duplex tray installed to save trees was used to print out laser proofs PDF files were created with Acrobat Distiller 4 0 A wind driven open window pr...

Page 19: ...e under warranty Note You must have a sales receipt from an authorized Mackie dealer for your unit to be considered for warranty repair IMPORTANT Make sure that the Service Request Number is plainly w...

Page 20: ...Road NE Woodinville WA 98072 USA United States and Canada 800 898 3211 Europe Asia Central and South America 425 487 4333 Middle East and Africa 31 20 654 4000 Fax 425 487 4337 www mackie com E mail s...

Reviews: