background image

SP2400 – 17

Paging Mic Control

The 

PAGING MIC CONTROL

 connector is

provided to connect a manual paging switch.
Connect a normally-open switch between 

GND

 and

ZONE A

 (to page in Zone A only), 

GND

 and 

ZONE B

(to page in Zone B only), or 

GND

 and 

ALL CALL

(to page over the entire system). The voice-
activated (

VOX

) control for the Paging Mic still

operates in both zones when the switch is off.

Local Mic/Line Inputs

Connect a microphone to 

MIC/LINE INPUT A or B

(one for each zone), using the supplied Phoenix-type
connector, to use for a meeting room or other local
speaking requirements. Set the 

PHANTOM

 and

GAIN +40dB

 switches to their appropriate positions.

Select the 

OFF

 button on the front panel. This

disengages the selected Program Source and
engages the 

MIC/LINE INPUT

. Adjust the 

MASTER

VOLUME

 up/down buttons so the meter level is at

the “

0

” mark.

Note:

 The 

MASTER VOLUME

 setting for the

MIC/LINE INPUTS

 is independent of the 

MASTER

VOLUME

 setting for 

INPUTS 1-4

. The 

MASTER

VOLUME

 setting for 

INPUTS 1-4

 is stored in

memory when the 

MIC/LINE INPUT

 is selected (the

OFF

 button is engaged). When an 

INPUT 1-4

 is

selected, the 

MASTER VOLUME

 setting for the

MIC/LINE INPUT

 is stored in memory.

Set the 

GAIN

 control so the meter indication is

near the “

0

” mark when speaking at an average

level into the microphone.

Set the 2-band EQ (

LOW

 and 

HIGH

) to the “

U

position. These can be adjusted later, if necessary.

Ambient Mic Inputs

This is an optional connection, but can greatly

enhance the performance of the Paging Mic.
Connect the optional MT-3100 mic to the 

AMBIENT

MIC

 input (one for each zone). This provides an

“ear” for the microprocessor to adjust the Paging
Mic gain to compensate for the ambient noise level
in the room. Use the supplied Phoenix-type
connectors to make these connections.

Note:

 Move the 

AMP ADDRESS

 switch #8 UP to

enable the ambient mic. See page 20 for more
information on "Using the Ambient Mic."

Expansion In/Out

If you are connecting two or more SP2400s in a

system, use the 

EXPANSION IN/OUT

 connections

to distribute the Program Input sources assigned to
the Expansion Bus between SP2400s. The two 25-
pin D-Sub connectors are in parallel (use one to
connect to the previous SP2400 and one to connect
to the next SP2400 in the chain).

REMOTE

You can connect one or more optional remote

controls (up to 10) to each zone on the SP2400 to
provide wall-mounted input select, program signal
volume control, and local mic volume control.

RS485

A PC can be connected to the RS485 port to

provide computer control for up to 16 SP2400s,
interconnected via their RS485 ports, using the
SPLinker Sound Palette Control software application.
If the PC doesn't have an RS485 serial port, you can
either install an RS485 interface card, or use an
RS232 serial port with an RS232-to-RS485 converter.

Two zones can be controlled with one wired

remote control by connecting the RS485 ports
between the two zones. (The RS485 ports are
connected internally, so an external connection
between the RS485 ports on a single SP2400 is not
necessary.) Each amplifier must have the same

AMP ADDRESS

 as the amp to which the remote

control is connected, with one assigned as Master
and the other as Slave. Use the supplied Phoenix-
type connectors to make these connections.

Note:

 Move the 

AMP ADDRESS

 switch #6

DOWN for Master and UP for Slave.

PRE OUT/AMP IN

These connections can be used to insert a signal

processor (i.e., graphic equalizer, compressor, etc.)
into the signal chain, or to feed the signal to additional
power amplifiers. If no external processor or external
amplifier is to be used, leave the U-shaped jumper in
place between the 

PRE OUT

 and 

AMP IN

 connectors.

OUTPUTS

Use the supplied two-conductor Phoenix-type

connectors with appropriate speaker wiring to
connect to the speaker or distributed speaker
system.

Summary of Contents for Sound Palette SP2400

Page 1: ...IN AMP ADDRESS ZONE B RS485 REMOTE AMBIENT MIC MIC VOX AMP IN PRE OUT HIGH 12k FREQ MID LOW 80Hz U 15 15 U 15 15 U 15 15 1K 3K 400 8k 250 HIGH U 12 12 U 12 12 LOW GAIN ZONE A AMP IN PRE OUT PAGING MIC...

Page 2: ...sion cord receptacle or other outlet unless the blades can be fully inserted to prevent blade exposure Pour pr venir les chocs lectriques ne pas utiliser cette fiche polarise avec un prolongateur un p...

Page 3: ...d in U S A 2 INTRODUCTION The SP2400 is a microprocessor based dual channel music controller with two built in power amplifiers designed for use in a variety of installations requiring high performanc...

Page 4: ...he local program input signal connected here or the program signal on the expansion bus See Expansion In Out on page 18 for more information DIRECT OUTPUT is a buffered line level output providing the...

Page 5: ...signal source even numbered switches Move the switches up to select the local program source and down to select the remote external program source from the EXPANSION bus STEREO MONO switches configur...

Page 6: ...MANUFACTURED BY MACKIE DESIGNS INC WOODINVILLE WA MADE IN USA FABRIQUE AU USA ZONE B OUTPUT 100 70V 8 STEREO RIGHT 1 2 3 4 1 2 3 4 5 6 7 8 MONO STEREO LOCAL 1 2 3 4 REMOTE 1 2 3 4 ZONE A OUTPUT 100 70...

Page 7: ...Hz U 15 15 U 15 15 U 15 15 1K 3K 400 8k 250 HIGH U 12 12 U 12 12 LOW GAIN AMP IN PRE OUT PAGING MIC EXPANSION IN EXPANSION OUT THE FOLLOWING ARE TRADEMARKS OR REGISTERED TRADEMARKS OF MACKIE DESIGNS I...

Page 8: ...12 LOW GAIN AMP ADDRESS RS485 REMOTE AMBIENT MIC MIC VOX AMP IN PRE OUT HIGH 12k FREQ MID LOW 80Hz U 15 15 U 15 15 U 15 15 1K 3K 400 8k 250 HIGH U 12 12 U 12 12 LOW GAIN AMP IN PRE OUT PAGING MIC EXP...

Page 9: ...30dB U M I C G A I N 0 60 30dB 30dB U M I C G A I N 0 60 30dB 30dB U PHANTOM POWER 48V DC 12 1 5V 11 G 1 G G G INPUTS OUTPUTS 100 240V 50 60Hz 1A MAX THE FOLLOWING ARE TRADEMARKS OR REGISTERED TRADEMA...

Page 10: ...P ADDRESS switch 6 This allows the front panel buttons for both zones and all the remote controls to operate both zones simultaneously When an input is selected it is heard in both zones because Zone...

Page 11: ...et to the down position as well 40 Note The Paging Mic has priority over the system including Input 4 5 Is there a manual switch for paging Up to three switches can be connected to the SP2400 PAGING M...

Page 12: ...utput is configured for 8 ohm operation connect the speaker output directly to an 8 ohm load The amplifier will deliver up to 250 watts to each speaker If the amplifier is configured for either 70V or...

Page 13: ...ttings Note There are several settings that can be changed inside the SP2400 These settings should be made prior to installing the SP2400 CAUTION These servicing instructions are for use by qualified...

Page 14: ...the locations of the jumpers Note Each amplifier board must be configured separately On the Amplifier Boards J1 Jumper pins 1 and 2 for 8 ohm operation Jumper pins 2 and 3 for 70V or 100V operation J2...

Page 15: ...sis to allow proper ventilation If installing three or more SP2400s in a rack use a fan in the rack to move cool air in and warm air out of the rack s enclosure It may be necessary to provide a cool a...

Page 16: ...e instruction manual which is the only way to fully understand how the SP2400 works However the Quick Start provides a quick overview so you can get the SP2400 set up and working right away Make sure...

Page 17: ...ADDRESS switch 8 UP to enable the ambient mic See page 20 for more information on Using the Ambient Mic Expansion In Out If you are connecting two or more SP2400s in a system use the EXPANSION IN OUT...

Page 18: ...operate both amplifiers In a zone configuration move the STEREO MONO switches down to combine the stereo signal into a mono signal for each program source Set the AMP ADDRESS switches to different add...

Page 19: ...u let go of the switch the music begins to ramp up to its original volume Note 2 When the manual switch is off the voice activated VOX control for the paging mic is still operational Ensure that the P...

Page 20: ...ibration Proce dure when used with Ambient Mic 1 Perform the Ambient Microphone Calibration Procedure described above 2 Switch the ambient mic OFF AMP ADDRESS switch 8 down 3 Adjust the MASTER VOLUME...

Page 21: ...Speaker Connection If the SP2400 is not being used in a distributed speaker system you can reconfigure the amplifiers to drive an 8 ohm load Each amplifier can provide up to 250 watts into an 8 ohm lo...

Page 22: ...connect the SP2400 to a computer loaded with the SPLinker software application The PC compatible computer must have an RS485 port to properly connect to the SP2400 It may be necessary to install an RS...

Page 23: ...TO EXPANSION I O BUS ASSIGN TO EXPANSION I O BUS ASSIGN TO EXPANSION I O TO EXPANSION I O FROM EXPANSION I O FROM EXPANSION I O FROM EXPANSION I O FROM EXPANSION I O FROM EXPANSION I O FROM EXPANSION...

Page 24: ...position 30 dB 100V position Maximum Input Level 12 volts P P 15 dBu Rise Time 5 S Slew Rate 17 V S Preamplifier Section Input Levels Program Inputs 10 dBu to 10 dBu for maximum output level with inte...

Page 25: ...y important Mackie Industrial is not responsible for any damage that occurs during shipping due to non conventional packaging Original packaging helps to minimize the possibility of shipping damage 3...

Page 26: ...operation Press 3 on Power Up Paging Mic Level Adjustment Press and hold the Input 3 button while powering up the SP2400 Release the Input 3 button The lowest Paging Mic level is indicated on the LED...

Page 27: ...3 R6 D1 F1 J3 J1 J4 J2 J8 J5 J11 J14 J9 J6 J10 J7 J13 J12 D2 JP1 R5 K1 R2 C2 4A SB 250V BROWN BLUE YELLOW YELLOW RED BLACK BLACK RED YELLOW YELLOW RED BLACK RED BLACK REMOVE JUMPER FOR 230V SP2400 230...

Page 28: ...SP2400 Music Controller Mackie Industrial 16220 Wood Red Rd NE Woodinville WA 98072 USA 888 337 7404 Outside the U S 425 487 4333 Fax 425 487 4337 www mackieindustrial com...

Reviews: