background image

Power Amplifier

UP4121

oF 6 PAGES

3

O F   4   P A G E S

LOW

EQ

HIGH

VOLUME

0

10

8

2

1

3

4

5

6

7

9

8

4

2

0

2

4

8

-10

+10

6

6

8

4

2

0

2

4

8

-10

+10

6

6

POWER

PEAK

O

VERL

O

A

D

SI

GNAL

ON

STD-BY

UP 4121 - P

.A. AMPLIFIER

+

POWER INPUT

24V D.C.

D.C. FUSE

VOLTAGE

SELECTOR

0

50V

70V

100V

INPUT

COMMANDS

0d

B

20

dB

ON

OFF

0

25V

PRIORITY

GND

UNBALANCED IN

GND

H.P.

FILTER

BALANCED

IN

L.P.

STAND

BY

SENSITIVITY

GND

PARALLEL OUT

OVERL.

300mA.

max

POWER OUTPUTS

CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE INDUSTRIAL • MADE IN ITALY • PATENTS PENDING • COPYRIGHT ©1999

SERIAL NUMBER

MANUF

A

CTURING D

A

TE

RISK O

F ELECTRIC SH

O

C

K

D

O NO

T O

PEN

REPLACE WITH THE SAME TYPE FUSE AND RA

TING.

DISCONNECT SUPPL

Y CORD BEFORE CHANGING FUSE

UTILISE UN FUSIBLE DE RECHANGE DE MÊ

ME TY

PE.

DEBRANCHER A

VANT DE REMPLACER LE FUSIBLE

W

ARNIN

G

TO

 REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT 

EX

POSE THIS EQUIPMENT TO RAIN OR MOISTURE. DO NOT REMOVE COVER. 

NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING T

O QUALIFIED PERSONNEL.

CAUTION

AVIS:

 

RISQUE DE CHOC ELECTRIQUE — NE P

AS OUVRIR

 TH

E FO

LLOWING ARE TRADEMARKS/REGISTERED TR

A

DEMARKS O

F M

ACK

IE DESIGN INC.: "MACKIE"

, "MACKIE INDUSTRIAL"

, & THE "RUNNING MAN" FIGURE 

-

LINE

     50/60 Hz-115/230V

POWER OUTPUTS

4

Summary of Contents for UP 4000 Series UP4121

Page 1: ...ge The output stage is fully pro tected against permanent damage caused by overload ing shorts and extreme temperatures The UP4121 will operate on either 115 or 230VAC 50 60Hz supplied by a detachable IEC power cord Insulated terminals to connect a back up 24Vdc battery are provided on the rear panel Switchover to DC is automatic A programmable stand by mode allows the amplifier to be turned on re...

Page 2: ... 50V 70V 100V barrier connectors Line Level Parallel to Unbalanced In RCA connector Control Inputs Outputs Outputs Overload Indicator 18Vdc 300mA Inputs Priority Switch Input Dry contact closure Stand by Switch Input Dry contact closure barrier connectors Controls Front Panel Power switch master Volume Treble shelving Bass shelving Rear Panel Unbalanced input sensitivity switch H P Filter in out s...

Page 3: ... IN ITALY PATENTS PENDING COPYRIGHT 1999 SERIAL NUMBER MANUFACTURING DATE RISK OF ELECTRIC SHOCK DO NOT OPEN REPLACE WITH THE SAME TYPE FUSE AND RATING DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE UTILISE UN FUSIBLE DE RECHANGE DE MÊ ME TYPE DEBRANCHER AVANT DE REMPLACER LE FUSIBLE WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE DO NOT REMOVE CO...

Page 4: ...anel An overload condition shall cause an auxiliary voltage of 18Vdc at 300mA to be present at a pair of terminals on the rear panel The unit shall have on its front panel continuously vari able controls for master volume as well as bass and treble shelving filters The shelving filters shall have a range of 12dB with the frequency for the bass fixed at 100Hz and the treble fixed at 10kHz LED statu...

Reviews: