General cleaning 

It is recommended to clean the Mackworth Essentials 180 Mobile Hoist and accessories before the use by a different patient, 

reducing the risk of cross–contamination. 
 
The exterior of the Mackworth Essentials 180 Mobile Hoist can be cleaned using a damp soapy cloth for general 

cleaning duties. Please ensure the cloth is damp and not wet. Ensure the exterior of the device is dry after cleaning. Dry using a 
clean dry cloth. 

 

 

Disinfecting (if necessary) 

Should the Mobile Hoist require a more thorough clean, the use of the Actichlor™ disinfectant product (which is widely available 
in tablet form and used throughout the health care industry) is recommended. 
 

Follow the manufacturer’s safety instructions for the use of the cleaning product before use to ensure safe use for 
the operator and the patient. 
Ensure the cloth is damp before the cleaning process.  

 
Application is through a clean damp cloth applied to wipe the device down. Use in the following dilutions to ensure an effective 
clean: 
 
 

 

Actichlor™ dissolvable chlorine tablets provide a concentration of 1000 ppm of available chlorine (0.1%) per 1 tablet 

 

1 tablet (1.7g formed tablet (x1)) will create a virucidal solution, diluted in 1 litre of water to provide effective means to 
clean a “dirty” device. This is also ideal for use after an outbreak of the Norovirus/winter vomiting and can be used as a 
precaution against C.Diff. It is effective against viruses, bacteria, spores, yeasts and moulds. 

 

The contact time against the outer components of the device should be for 5 minutes to prevent any virucidal 
infections without a degradation to the functionality of the device. 5 minutes is a recommended contact time. The 
device can withstand a longer contact period but the 5 minute recommendation as a minimum must be followed to 
provide an effective cleaning regime.  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 180 Mobile Hoist

Page 1: ...Doc No 993051 Revision of document A Revision Date 24 05 21 Pre Sales Information 180 Mobile Hoist...

Page 2: ...3 Open Close Mobile Hoist Legs 4 Handset Operations 4 Slings 5 Technical Specification 13 Specifications 14 Environmental Storage and Operating Conditions 14 Normal Operating Conditions 14 Shipping a...

Page 3: ...a carry bar and straps and holds the client during the lift transfer Please refer to the user guides supplied with the sling and reference them while reviewing this manual The functions of raising an...

Page 4: ...and or passages the Mobile Hoist legs should be in the closed position Handset Operations The Hand Controls has 4 functions Up and Down this will raise and lower the Mobile Hoist and Legs Open and Le...

Page 5: ...t to be utilised with the Mackworth Essentials 180 Mobile Hoist It is at the user s discretion to use alternative supplied product In utilising another manufacturer s sling checks must first be made t...

Page 6: ...W7320 1201YW8320 1201YW3320 n a 1201YW4320 XL 1201YW7220 1201YW8220 1201YW3220 n a 1201YW4220 XXL 1201YW7120 1201YW8120 1201YW3120 n a 1201YW4120 XXXL 1201YW7020 1201YW8020 1201YW3020 n a 1201YW4020 M...

Page 7: ...20 1201BC8320 1201BC3320 1201BC5320 1201BC4320 XL 1201BC7220 1201BC8220 1201BC3220 1201BC5220 1201BC4220 XXL 1201BC7120 1201BC8120 1201BC3120 1201BC5120 1201BC4120 XXXL 1201BC7020 1201BC8020 1201BC302...

Page 8: ...400PP4 CA400MP4 CA400SP4 CA400PAP4 P5 CA400PP5 CA400MP5 CA400SP5 CA400PAP5 X Small CA400PXS CA400MXS CA400SXS CA400PAXS Small CA400PS CA400MS CA400SS CA400PAS Small Medium CA400PSM CA400MSM CA400SSM C...

Page 9: ...l CA502PS CA502MS CA502SS CA502PAS Small Medium CA502PSM CA502MSM CA502SSM CA502PASM Medium CA502PM CA502MM CA502SM CA502PAM Medium Large CA502PML CA502MML CA502SML CA502PAML Large CA502PL CA502ML CA5...

Page 10: ...00MXS CA700SXS CA700PAXS Small CA700PS CA700MS CA700SS CA700PAS Small Medium CA700PSM CA700MSM CA700SSM CA700PASM Medium CA700PM CA700MM CA700SM CA700PAM Medium Large CA700PML CA700MML CA700SML CA700P...

Page 11: ...dium Large CA702PML CA702MML CA702SML CA702PAML Large CA702PL CA702ML CA702SL CA702PAL X Large CA702PXL CA702MXL CA702SXL CA702PAXL CA702 Comfort In Chair Hammock with head support P1 CA702HSPP1 CA702...

Page 12: ...8 Small Medium CA703PSM CA703MSM CA703SSM CA703PASM Medium CA703PM CA703MM CA703SM CA703PAM Medium Large CA703PML CA703MML CA703SML CA703PAML Large CA703PL CA703ML CA703SL CA703PAL X Large CA703PXL CA...

Page 13: ...993051 Revision A P a g e 13 of 18 Technical Specification All dimensions below are shown in millimetres Figure 15 Figure 16...

Page 14: ...be used in environments where there are rapid changes in the environmental temperature and humidity during use Normal Operating Conditions 5 C to 40 C 41 F to 104 F at a relative humidity between 15 t...

Page 15: ...than the regular charging as detailed in the charging instructions Emergency Stop Button Check the emergency stop button functionality Manual Emergency Lower Check the manual emergency lower functiona...

Page 16: ...tor and the patient Ensure the cloth is damp before the cleaning process Application is through a clean damp cloth applied to wipe the device down Use in the following dilutions to ensure an effective...