Instruction Manual
Page 8
IMPELLER AND O’RING REPLACEMENT
1) Unscrew adapter
2) Remove o’ring.
3) Remove impeller housing.
4) Remove o’ring.
5) Carefully remove and replace impeller.
6) Replace o’ring.
7) Carefully insert impeller housing.
(Note correct orientation of grooves)
8) Replace o’ring.
9) Firmley hand tighten pump tube.
Note: Impeller must be lubricated with
oil or grease during assembly.