IM213D-MC Issue 10 © 2017                                                                                                                                                                 Page 2 of 8 

Operational Overview 

1. During normal operation the 6 Figure LCD display 

will appear as per the example diagram below. 

 
 
 
 
 
 
 
 
 
 
 
 
2. Pressing the blue ‘

Mode

’ button will enable the 

  operator to toggle between the following two 
  Display options. 
 

• 

Batch 

• 

Total 

 
3. The ’Batch’ total can be reset by pressing the red 
  ‘

Reset

’ button. 

 
 

Please note:  

  This function resets the ‘

Batch

’ only. The  

  ‘

Total’

 displayed is unable to be reset. 

 

4. A ‘

Sleep

’ mode has been incorporated in the 

  meter to prolong battery life. The unit will activate 
  sleep mode after 30 secs without use. 

 

2. Pressing the blue ‘

Mode

’ button will cycle through 

  options available 
 

• 

 

dEC .1     

= 1 Decimal Place

 

• 

 

dEC .22   

= 2 Decimal Places

 

• 

 

dEC .333 

= 3 Decimal Places

 

 

3

To move to the next section (Unit) press the red 

  ‘

Reset

’ button 

 
 
Setting the Units for both Batch & Total. 

1. The LCD will now display ‘

UNIT

’.  

  See ‘

Operational Overview’

.  

 
2. Pressing the blue ‘

Mode

’ button will cycle through 

  the options of units that can be displayed for 
  Batch. 
 

• 

• 

GAL 

• 

Qt 

• 

Pt 

• 

Oz 

• 

dL 

 

3. Next press the red ‘Reset’ button to move onto 
  setting the ‘Total’ units. The availible unit options 
  are as shown above. 
 
 
4.  Once the required ‘Units’ have been selected 
  move  

to the next section (Calibration) by 

  pressing the Red ‘

Reset

’  button.

 

Programming Instructions 

Note 

Any changes made during the programming 
phase will automatically be ‘

Saved’

 when the unit 

is returned to the operation mode. 

Accessing ‘Programming’ Menu 

To enter in the programming ‘Menu’, press the reset 
button for 5 secs. 

Once in the programming menu the operator will be 
able to access (and adjust) 3 programming 
selections. 
 
 

1-  Setting Decimal Place 

 

2-  Display Units of measurement 

 

3 - Calibration Mode 

Setting the decimal place. 

1.The unit will display the mode and the number of 
  Decimal Places currently set.  
  E.g. ‘ 

dEC .22

” 

Calibration.

 

The calibration mode enables, in the case the 
operator suspects the accuracy of the meter is in 
question, the operator to dispense a known volume 
of fluid through the meter (Test Volume)  
This Test Volume is compared to the volume 
measured by the meter (Measured Volume). The 
meter will perform an ‘Auto Calibration’ if applicable. 
 

1. 

The unit will display ‘

CALIBRATE

’ in the 

lower left  

hand corner, and a number on 

the main display.  

 
The following options can be scrolled through by 
pressing the blue 

Mode

 button 

 

  4 

  8 

  20 

  100 

  250

 

 

 
This number represents the ‘Test Volume’ to be 
dispensed through the meter during Calibration. 

Summary of Contents for IM012E

Page 1: ...design This has proven to be a reliable and highly accurate method of measuring flow Exceptional repeatability and high accuracy over a wide range of fluid viscosities and flow rates are features of the oval rotor design With a low pressure drop and high pressure rating oval rotor flow meters are suitable for both gravity and pump in line Before use confirm the fluid to be used is compatible with ...

Page 2: ...as shown above 4 Once the required Units have been selected move to the next section Calibration by pressing the Red Reset button Programming Instructions Note Any changes made during the programming phase will automatically be Saved when the unit is returned to the operation mode Accessing Programming Menu To enter in the programming Menu press the reset button for 5 secs Once in the programming ...

Page 3: ...ing the rotors the top face of the rotors should be flush with the sealing face of the meter body If they sit higher than the sealing face remove turn over and replace 2 Replace the rotors Item 6 onto the shafts at 90 degrees to each other as per diagram below and check their operation by turning either of the rotors If the rotors are not in mesh correctly or do not move freely remove one of the r...

Page 4: ...mbly procedure Follow step 1 to isolate the Electronic module 2 See Photograph below Remove the PCB from clear plastic housing by unscrewing the 3 retaining screws 3 The battery can now be removed by placing a screw driver into the slot slot indicated by arrow on the PCB and easing the battery free from its compartment 4 Replace with a new CR2450 Lithium battery Yellow Green Reed Switch Please Not...

Page 5: ...s Order for replacement Item no No off Part or Set Description 1 1 IM215s Protective boot 2 7 Screw M3 x 8 Pan Hd 3 1 DKIT IM012 MC Electronic module 4 1 O ring BS040 5 1 n a Body 6 2 MKIT IM012 01 Rotor 7 1 O ring BS035 8 1 n a Cover plate 9 8 n a Screw M4 x 16 Pan Hd ...

Page 6: ...IM213D MC Issue 10 2017 Page 6 of 8 Meter Dimensions Notes ...

Page 7: ...otors see instructions Meter not giving a pulse signal a Faulty hall effect sensor b Faulty reed switch c Magnets failed a Replace PCB Board b Replace PCB Board c Replacement rotor assembly required LCD register not working a Battery flat b Faulty LC Display a Replace battery b Replace PCB module WEEE Directive Waste Electrical and Electronic Equipment The WEEE Directive requires the recycling of ...

Page 8: ... Ethelene Glycol Based Anti Freeze Anti Boil mixture Max 50 w ater Wetted Materials Acetal Aluminium Steel Nitrile Rubber Connections 1 2 BSPT or 1 2 NPT Maximum Temperature 55 deg C 131 deg F Minimum Temperature 14 deg C 6 8 deg F Maximum Viscosity 1000cP Centipoise Re settable Batch Total 99999 9 Non Resettable Total 999999 Note This product should be disposed of according to all applicable loca...