IM213D-MC Issue 10 © 2017 Page 4 of 8
Maintenance Procedures
Changing the Battery.
A ‘
Low Battery’
warning will be displayed on the
LCD screen when there is 5% power left.
The warning will remain active until the battery is
replaced.
1. See ‘
Disassembly
’ procedure.
Follow step 1 to isolate the Electronic module.
2. See ‘
Photograph
’ below.
Remove the PCB from clear plastic housing by
unscrewing the 3 retaining screws.
3. The battery can now be removed by placing a
screw driver into the slot (
slot indicated by arrow
)
on the PCB and easing the battery free from its
compartment.
4. Replace with a new CR2450 Lithium battery.
Yellow
Green
Reed Switch
Please Note: Not dependant on Polarity
Battery Slot