background image

7) Place the reel in a vertical position and while  holding
        the  reel  pull  the  hose  out  past  the  last  clicking  niose
    and carefully guide the hose onto the drum

8) If the replacement hose is the same lenght as the old
      hose  no  tension  adjustment  is  necessary.  If  spring
      tension  adjustment  is  required  rerer  to  the  “  Spring
    tensioning and latch side plate removal” proceedure.

SPRING TENSION AND LATCH SIDE
PLATE REMOVAL

1) Place reel on a clean bench with latching plate (9) face
     up.

2)  Release  spring  tension  by  opening  tension  plate  (8)
      and    place  handle  of  a  pair  of  pliers  in  the  exposed
      slots. Grip the pliers firmly and remove the two screws
        holding  the    tension  plate  (8)  and  carefully  allow  the
     tension plate to slowly unwind counter clockwise.

3)  Remove  screw  holding  tension  plate  and  remove
        tension  plate.  Remove  screw  located  at  the  edge  of
     the latching plate.  Turn latching plate clockwise and
     remove, this will expose the latching cup assembly.

4) To replace latching plate, suspend reel between your
     body and edge of the bench.  Reposition the plate and
    turn counter clockwise. Relocate side screws, replace
     tension plate and fixing screw.

5)  Reload  spring  tension  by  using  the  same  tool  (as  in
        step  2)  and  wind  tension  plate  clockwise  until  hose
      stopper  is  firmly  against  the  reel  mouth,  some
     resistance will be felt. Then add approximately six (6)
        complet  360  deg.    tetension  turns.    Hold  the  tension
      plate in this position align dimples on tension plate la
       latching side plate and replace the two screws.  Close

CAUTION

Test the reel for leaks prior to any further use

4

CAUTION

Test the reel for leaks prior to any further use.

     tension plate and cover.

Reviews: