background image

Page 14

Reference Manual

Macro-Tech

®

 24x6 & 36x12 Power Amplifiers

shielded pair cable is another effective way to reduce
or eliminate hum resulting from inductive coupling.

Ground loops often result when two or more devices
are improperly grounded. This causes undesirable
stray currents that may produce hum in the output. The
best way to avoid ground loops is to ensure that all sys-
tem devices are plugged into the same power strip. In
addition, make sure that all cable shields are grounded
at one end only.

Input and output grounds are sometimes tied together
for testing or metering. This can cause 

feedback oscil-

lation

 from load current in the test loop. In some sys-

tems, even the AC power line may provide this
feedback path. Proper grounding, input isolation and
isolation of common AC devices in the system is good
practice.

3.3.2 Output Connection

Consider the power-handling capacity of your load be-
fore connecting it to the amplifier. Crown is not liable for
damage incurred at any time due to a load being over-
powered. The use of loudspeaker protection fuses is
highly recommended (see Section 3.3.3). Also, please
pay close attention to the Operating Precautions in Sec-
tion 4.1.

HOW TO DETERMINE

APPROPRIATE WIRE GAUGE

It is important to use loudspeaker cables with sufficient
gauge (thickness) for the length being used. The resis-
tance introduced by inadequate loudspeaker cables
will reduce both the output power and the motion con-
trol of the loudspeakers. The latter problem occurs be-
cause the damping factor decreases as the cable

Use Good Connectors

1. To prevent possible short circuits, do not
expose the loudspeaker cable connectors.

2. Do not use connectors that might
accidentally tie two channels together when
making or breaking connections (for example, a
standard three-wire stereo phone plug).

3. Connectors that can be plugged into AC
power receptacles should never be used.

4. Connectors having low current-carrying
capacity should not be used.

5. Connectors with any tendency to short
should never be used.

resistance increases. This is very important because
the amplifier’s excellent damping factor can easily be
negated by insufficient loudspeaker cables.

Use the nomograph in Figure 3.11 and the procedure
that follows to find the recommended wire gauge (AWG
or American Wire Gauge) for your system.

Fig. 3.11  Wire Size Nomograph

40

30

20

15

10

9

8

7

6

5

4

3

2

1

2

5

10

20

50

100

.04

.06

.1

.2

.4

.6

1

2

4

6

10

20

40

8000

Ohms/1000 Feet

(305 Meters)

AWG (American
Wire Gauge)

Feet

Meters

5000

1000

500

100

50

10

5

1

.5

.1

.05

.01

#28

#26

#24

#22

#20

#18

#16

#14

#12

#10

#8

#6

#4

#2

#0

#00

#0000

R

L

Load

Resistance

(Ohms)

R

L

R

S

Damping

Factor

R

S

Source

Resistance

(Ohms)

Two

Conductor

Cable

Copper

Wire

Example Shown:

Load Resistance = 8 ohms

Desired Damping Factor = 500

Source Resistance = 0.016 ohms

Cable Length = 10 feet (3.1 meters)

Recommended Wire: #8 AWG or equivalent
wire with 1.75 ohms or less resistance per
1000 feet (305 meters).

1

0.5

200

500

1,000

2,000

20,000

5,000

10,000

.01

.001

.02

.004

.006

.002

.0004

.0006

.0002

0.3

1.5

0.6

3.1

6.1

15.3

30.5

61.0

152.5

305.0

610.0

1525

1

5

2

10

20

50

100

200

500

1000

2000

5000

.0002

0.6

0.7

0.8

1.5

0.9

Summary of Contents for 24x6

Page 1: ...ifiers are produced by the Professional Audio Division of Crown International Inc Trademark Notice SmartAmp Grounded Bridge and PIP are trademarks and Amcron Crown Macro Tech IOC ODEP IQ IQ System and...

Page 2: ...nalpurchaser the warrantyperiod thatthenewCrownproductisfreeofdefectsinmaterials and workmanship We further warrant the new Crown product regardless of the reason for failure except as excluded in thi...

Page 3: ...RISK OF ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE Magnetic Field CAUTION Do not locate sensitive high gain equipment such as preamplifiers or tape decks directly above or below...

Page 4: ...ded plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience recepta...

Page 5: ...tion Systems 18 4 3 1 ODEP 18 4 3 2 Standby Mode 19 4 3 3 Transformer Thermal Protection 19 4 3 4 Circuit Breakers 19 4 4 Controls 19 4 5 Filter Cleaning 20 5 Technical Information 21 5 1 Overview 21...

Page 6: ...3 11 Wire Size Nomograph 14 3 12 Inductive Load Transformer Network 16 3 13 Loudspeaker Fuse Selector Nomograph 16 4 1 Indicators 17 4 2 ODEP and Signal IOC Indicator States 18 4 3 Input Sensitivity a...

Page 7: ...ect condition as most do save all packing materials so you will have them if you ever need to transport the unit NEVER SHIP THE UNIT WITHOUT THE FACTORY PACK 1 2 Features Here are some of the impressi...

Page 8: ...her IOC function is to indicate input overload If an input signal is too large the indicator for the affected channel flashes brightly with a 0 5 second hold delay to show clipping distortion D ODEP I...

Page 9: ...e they are electrically in parallel with the PIP in put connectors input signals should not be connected to the phone jacks when certain PIP modules are in stalled see Section 3 3 1 The phone jacks ca...

Page 10: ...ters etc to prevent rapid loading of the unit s own air filter When needed the unit s filter can be cleaned with mild dish detergent and water see Section 4 5 When mounting the amplifier in a rack cab...

Page 11: ...l eliminate any chance of loud blasts or damage to the loudspeakers Because each channel produces a different power level the Macro Tech 24x6 and 36x12 are dedicated to Fig 3 4 Wiring a Macro Tech 36x...

Page 12: ...ed Input Wiring Fig 3 7 Balanced and Unbalanced Phone Plug Wiring a standard tip ring sleeve TRS configuration the tip is positive the ring is negative and the sleeve is ground see Figure 3 7 Wiring f...

Page 13: ...t energy and can drive loudspeakers to levels which can cause permanent hearing damage Crown is not liable for personal injury or damage incurred when a transducer or component is over driven Fig 3 10...

Page 14: ...akers The latter problem occurs be cause the damping factor decreases as the cable Use Good Connectors 1 To prevent possible short circuits do not expose the loudspeaker cable connectors 2 Do not use...

Page 15: ...wires can be used for the same effect SOLVING OUTPUT PROBLEMS Sometimes high frequency oscillations occur that can cause your amplifier to prematurely activate its protec tion circuitry which can res...

Page 16: ...unless otherwise noted Speci fications were derived using a voltage that is accurate to within 0 5 with THD less than 1 0 under all testing conditions Performance variations can occur at other AC vol...

Page 17: ...re event that there is no re serve the indicators turn off and ODEP proportionally limits the drive level of the output stages so the ampli fier can continue safe operation even when conditions are se...

Page 18: ...dio output Possible reasons 1 There is no input signal 2 The input signal level is very low 3 The channel s level control is turned down ODEP SIGNAL IOC ON Normal Normal operation for a channel with a...

Page 19: ...is excessive heat The switch automatically resets when the transformer cools to a safe temperature It is very unlikely that you will ever see a Macro Tech amplifier activate transformer thermal prote...

Page 20: ...nly the phone jack inputs and has no affect on the PIP mod ule input connectors Sliding the switch to the left iso lates or lifts the grounds by placing an impedance between the sleeve of each input p...

Page 21: ...nd PNP devices Each output stage has two composite NPN devices and two composite PNP devices The devices connected to the load are referred to as high side NPN and PNP and the devices connected to gro...

Page 22: ...signed to prevent audible switching distor tion and yield the highest possible dynamic transfer function you hear only the music and not the amplifier You get not only the maximum power with the maxim...

Page 23: ...iescent voltage D309 D310 D311 and a trim mer resistor set the quiescent current point for the bridge balanced output stage The protection mechanisms that affect the signal path are implemented to pro...

Page 24: ...OWN NPN HI OUTPUT STAGE NPN LOW OUTPUT STAGE PNP LOW OUTPUT STAGE PNP HI OUTPUT STAGE OUTPUT Vcc Vcc TRANSLATOR LVA LVA Vcc Vcc BIAS CURRENT LIMIT TRANSLATOR BALANCE INPUT STAGE P I P BALANCED INPUTS...

Page 25: ...acro Tech 36x12 Channel 1 3600 124 6 1 12 or 41 9 dB 1 0 dB Macro Tech 36x12 Channel 2 1200 64 1 12 or 36 dB 0 5 dB Power Output Power The following are guaranteed minimums for standard 1 kHz power at...

Page 26: ...5 V and 1 4 V for rated output or a fixed voltage gain of 26 dB see Section 4 4 Output Signal Unbalanced two channel Output Connector A pair of color coded 5 way binding posts for banana plugs spade l...

Page 27: ...Page 27 Reference Manual Macro Tech 24x6 36x12 Power Amplifiers Fig 6 1 Typical Frequency Response Fig 6 2 Typical Damping Factor Fig 6 3 Typical Output Impedance...

Page 28: ...nual Macro Tech 24x6 36x12 Power Amplifiers TECHRON TEF 45 0 45 100 1 K 10 K 20 K FREQUENCY Hz Fig 6 4 Typical Phase Response Fig 7 1 Macro Tech 24x6 Power Draw Current Draw and Thermal Dissipation at...

Page 29: ...c is 20 Duty cycle of continuous speech is 10 Duty cycle of infrequent short duration paging is 1 Here are the equations used to calculate the data pre sented in Figures 7 1 and 7 2 AC Mains Power Dra...

Page 30: ...mplifier can be monitored and individu ally controlled from an inexpensive PC A total of 15 func tionscanbeeithermonitoredorcontrolled Memorybackup is also incorporated in case of power failure Requir...

Page 31: ...ssor but a circuit to preventanyoverload Itcanyieldupto13dBoradditional signal safety margin without noticeable program change P I P EDCbState of the artprogrammableerror drivenand signal driven compr...

Page 32: ...l Shaft Lock A security accessory the shaft lock can be used to secure your amplifier s level controls in situations where the front panel controls are subject to tampering One is needed for each chan...

Page 33: ...warranty service we will pay for ground shipping both ways in the United States Contact Crown Factory Service or Technical Support to obtain prepaid ship ping labels prior to sending the unit Or if y...

Page 34: ...________________ ______________________________________________________________________________ ______________________________________________________________________________ _________________________...

Reviews: