7 .Troubleshooting

How to handle exceptions
Note: Non-technical personnel do not disassemble and repair

Common Faults

Cause of failure

Treatment Method

The motor does not run

when the light is off

No power supply at home

Poor contact between plug and
socket

Wait for the power supply to work in
your home and try again,
Have it checked by a professional

Power cable break

The fuse is blown out

Call supplier for more information

The light is out

Motor rotation normal

The LED cold light is broken

The power module or control panel
is faulty

Call supplier for more information

The light is on;

Motor does not rotate

Motor over-temperature protection
action

Burnt out capacitor

Motor burn out

The power module or control panel
is faulty

Call supplier for more information

Violent body vibration;

Increase in noise

Check whether the range hood is
firmly suspended;
There is too much oil on the
impeller;
Check whether external screws
are loose

Hang the range hood securely;
Please have it professionally cleaned;
Key lime screw

Check whether the internal screws
are loose;
Whether the impeller is installed
properly;
Impeller damaged or missing
balance block

Call supplier for more information

The suction is not

strong

Too much air convection or too
tight seal in the kitchen;
Smoke pipe is too long, too many
turns

Reduce air convection or moderate
door opening, window non-technical
failure

It's too windy outside;
Installation height is too high

Call supplier for more information

The shell feels tingling

It's damp and the housing is not
properly grounded

Have it checked by a professional

Summary of Contents for CXW-300-T2C

Page 1: ...ards GB 4706 1 2005 GB 4706 28 2008 GB 29539 2013 GB T 17713 2011 Content 1 Safety Precautions Safety precautions 2 2 Important Information 4 3 Product Information 4 4 Installation Instructions 6 5 In...

Page 2: ...rofessional personnel Non professional maintenance personnel are absolutely prohibited to change the internal wiring of range hood without permission Do not touch the power plug electrical parts and p...

Page 3: ...tion The range hood should use a special power socket and the special power socket should be reliably grounded The ambient temperature of the range hood cannot exceed 40 C Exterior parts such as decor...

Page 4: ...contain reusable materials Please help to dispose or recycle them to make a contribution to environmental protection Before using a new range hood If the range hood is obviously damaged do not install...

Page 5: ...kg Gross weight 21 5 kg Product size 895mm x 450mm x 600mm Product package size 1010mm x 670mm x 553mm Note 1 In the clean mode the maximum air volume is 20m min 2 The allowable difference between th...

Page 6: ...too large holes to prevent the expansion tube from loosening and causing accidental fall Do not install the range hood in the bathroom or a place with high humidity It may cause electric shock When in...

Page 7: ...od prepare the following tools 1 Impact drill with drill bit 2 Screwdriver 3 Tape measure Preparation of attachments Accessories should be prepared when installing the range hood see attachment list I...

Page 8: ...8 Mounting size drawing Installation dimensions are shown in Figure 3...

Page 9: ...rresponding positions on the wall drill the mounting holes in the holes with a drill bit firmly bury the plastic expansion tube and then tighten the wooden screws Install the check valve air damper as...

Page 10: ...il Mounting the body Lift the whole machine as shown in Figure 8 The mounting holes on the back of the box are aligned with the hooks on the mounting plate Then fix the limit screws in the accessory b...

Page 11: ...ed shutdown state the default low speed 90s the countdown ends the shutdown of the whole machine Cleaning function open concern change button The cleaning function runs for 3 minutes After cumulative...

Page 12: ...of the range hood immediately after using it 2 Please wipe the outer surface of the lampblack machine with a soft wet towel or a towel stained with neutral detergent and then wipe the body with a soft...

Page 13: ...The power module or control panel is faulty Call supplier for more information Violent body vibration Increase in noise Check whether the range hood is firmly suspended There is too much oil on the im...

Page 14: ...y please contact the special maintenance department designated by the company or the service center in each region of the company We will serve you warmly Thank you for your cooperation Attached Elect...

Reviews: