© 2015 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com 42
Rev. Date 090415
4.2 Guy Wire Cord Installation
Components:
A - Guy Wire Cord
B - Eyelets
C - Cord Lock
4.2.1:
Insert the elastic cord through the
top eyelet of each of the 4 turnbuckles as
shown in pictures 1 & 2.
4.2.2:
Pull one of the ends of the cord
through one of the holes on the cord lock
and then pull the end into the groove to
lock it. Use pliers to properly secure the
cord in the groove of the cord lock as
shown in pictures 3 & 4.
4.2.3:
Repeat step 4.2.2 for the second end
of the cord using the opposite hole and
groove on the cord lock.
4.2.4:
The safety cord should be pulled
tight and fastened as shown in picture 5.
NOTE:
The Guy wire cord is a redundant
safety system for our fans. The Guy
Wire Cord Kit applies to our fans with
turnbuckles installed on the Guy wires.
The turnbuckles may have been supplied
by the installer or factory supplied
by MacroAir. This system utilizes a
polymer cord to secure the ends of the
turnbuckles. In the event that one or more
comes loose due to stresses that exceed
their capacity, the turnbuckles would
be captive above the airfoils and prevent
additional damages and down time to your
fan.
THE CORD IS CUT TO A
PREDETERMINED LENGTH
FOR PROPER TENSION.
DO NOT EXCESSIVELY
STRETCH THE CORD.
Picture 1
Picture 2
Picture 3
Picture 4
Picture 5
A
B
C