© 2018 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com 71
Rev. Date 040218
Code
Name
Code
Type
Factory
Setting
Description
Symptoms
Troubleshooting Tips
1014
Sudden Change
Of Speed
Auto-
Reset
20%
10 rpm
0.1 sec.
The controller looks
for a % change in
speed bounded by
a minimum RPM
change in a certain
amount of time. If
both conditions are
met, then the drive
will disable.
Fan Speeds Up
Suddenly
Fan “Twitches”
Fan Will Not
Run
Fan Stops
Suddenly
1. Ensure that blade length is properly
set
2. Perform a drive calibration
3. Confirm incoming power is within
fan’s specifications
4. Confirm motor values. Perform power
calibration if possible/necessary
1015
Tilt Limit
Exceeded
Auto-
Reset
+/- 5 °
Fan Wobbles
Fan Stops
Running
Fan Will Not
Start
1. Confirm that the tilt is below 5
degrees
2. Confirm that fan or structure is not
wobbling
3. Confirm that locking hardware on
mount is tight
4. Add guy wires if necessary
5. Disable tilt if guy wires are installed
1016
Vibration Limit
Exceeded
Auto-
Reset
Fan Vibrates
Fan Wobbles
Fan “Twitches”
1. Confirm that fan or structure is not
wobbling
2. Confirm that locking hardware on
mount is tight
3. Add guy wires if necessary
1017
Keep-Alive
Timeout
Auto-
Reset
10s
Fan Randomly
Stops
Fan Will Not
Start
1. Confirm whether touchpad was
unplugged or not
2. Confirm that CAT5 is under 100ft
3. Confirm that CAT5 is from factory and
has not been modified
4. Confirm that CAT5 is shielded
5. Confirm that repeaters are properly
installed on the network
6. Double check network splices
7. Plug touchpad directly into board
Troubleshooting