Page
22
MacroAir Technologies Inc. www.macro-air.com Toll Free: 866-668-3247 Build: January 9 2009
connections at the motor.
Always properly ground the installation!
For
eco
6 Guard Fans Without Safety Screens, Skip Steps 4 and 5.
Step 4
, Attach Rear Safety Screen
If ordered, safety screens MUST be installed to prevent injury in the unlikely event of fan failure.
A)
From the front of the fan, maneuver the rear screen over the motor plate to the rear.
B)
Line up the holes in the screen struts with the holes in the motor mount plate.
C)
Securely attach the screen to the motor mount plate using the supplied bolts, washers,
and nylon lock nuts, being sure to put the bolts in from the front.
Step 5
, Attach Hub And Hub Cover
A)
Slide the hub over the gearbox output shaft, flat side out, and position it approximately
flush with the end of the shaft.
B)
Insert the cone-shaped keyless bushing adapter over the shaft and into the hole in the
hub center bushing.
C)
Line up the four non-threaded holes in the keyless bushing adapter with the four
threaded holes in the hub center bushing.
Fig 12