background image

MA-BC04 

 

 

 

MESD-BC SERIES 

 

 
 
 

 

 

 
 

 

 

 

Please read the instructions carefully before using the ionizer, and keep it for 

future reference.

BAR TYPE IONIZER INSTRUCTIONS 

 

Summary of Contents for MESD-BC Series

Page 1: ...MA BC04 MESD BC SERIES Please read the instructions carefully before using the ionizer and keep it for future reference BAR TYPE IONIZER INSTRUCTIONS...

Page 2: ...Abnormal Wiring Figure 5 Power Supply 6 Installation 6 Manual guide 7 ID Control Adjust and Remote Setting 7 Remote Controller Instruction 8 Remote Controller Valid Range 8 Ion Proportion Setting 9 S...

Page 3: ...tem status display 6 Assisting nozzle 7 Quick released nozzle Please ensure you have following items on hand when receive the product The needle point of electrode probe generates ion by corona discha...

Page 4: ...034 990 956 879 1 16 MESD BC132 1267 1223 1189 1112 1 20 MESD BC156 1500 1456 1422 1345 1 24 MESD BC180 1733 1689 1655 1578 2 28 MESD BC204 1966 1922 1888 1811 2 32 MESD BC228 2199 2155 2121 2044 2 36...

Page 5: ...5 Product Specification Abnormal Wiring Figure Output method Open collector Brown White Black Blue Black...

Page 6: ...me the needle point of electrode probe could attach crystallized particle or dust due to moisture If meet this problem please wipe the needle point of electrode probe slightly by alcohol cotton or sof...

Page 7: ...the remote controller valid range 5 After setting up the channel press the icon on the remote controller to turn on the ionizer 6 Press arrow icon and on the remote controller to adjust the Ion propor...

Page 8: ...n the ionizer The infrared transmitter Press ID channel on the remote controller corresponds to ID setting knob on the ionizer ID adjustment panel Press and pull out the battery pack to change the bat...

Page 9: ...nation effective zone and time Ion proportion Setting Ion proportion Setting d70 d65 d60 d55 d50 Positive ions Negative ions 70 30 65 35 60 40 55 45 Ion proportion Setting d30 d35 d40 d45 50 50 Positi...

Page 10: ...10 Frequency Setting Location Operating Distance mm Frequency Short Distance 100 300 45 30Hz Middle Distance 300 1000 30 20Hz Far Distance 1000 2000 15 10Hz...

Page 11: ...shows the current frequency and can adjust it n 1 The current ID is 1 and so on Balance Ion output achieves an ion balance state Negative ions more than positive ions Positive ions more than negative...

Page 12: ...Electrode probe Assisting nozzle Wire color Description Brown DC24V Voltage Blue Ground wire 0V White Abnormal output signal Black GND output signal Orange Ground wire for connecting with the machine...

Page 13: ...age Most important is that you must turn off the power before maintenance otherwise it may cause danger or product damage It may cause danger due to touch the electrode probe directly during the maint...