5  Scans 

Arrow Mobile Android can scan both wMbus 868 

and 169 radios. They have different scan modes. Fixed 

frames can be detected by shifting the cursor from the 

map screen and then activating “

FIXED FRAMES

N.B.: once a scan has been launched, all other options 

are excluded and the display automatically switches to 

map display mode.

5.1  wMBus 169 scan

Maddalena wMbus 169 radios can be scanned either 

collectively (broadcast mode) or individually (unicast). 

The protocol employed by 

Maddalena radios is a strict 

implementation of EN13757, and hence is able to receive 

any radio compliant with that standard, even if it is not a 

Maddalena device.

All readings are saved: both those of the radios included 

in the database and those outside it. 

When smart metering is in progress, the partial results 

are summarised in the grey “COLLECTED DATA” bar lo-

cated at the base of the map.

The readings received among all the meters present in 

the database (in this case, 3 out of 10) and the number of 

messages of other radio modules received (in this case, 

57) are indicated. There may be radio modules not in-

serted in the database or radio modules of other man-

ufacturers

5.1.1  Broadcast scan 

To start the scan, click on “

START” or select “START NEW 

SCAN” on the home page. 

The terminal will launch a broadcast scan, i.e. a scan of 

all 

Maddalena radios, whether in the database or not.

Once the scan of the meters has started, 

Arrow Mobile 

Android automatically switches to map display mode. 

When the view is zoomed out, the meters display as clus-

ters, i.e. as groups of meters, to simplify the display.

If you zoom in, you can view the details of the individual 

meters.

Click on a single meter to open a window with detailed 

information (serial number, meter, address). Click on 

DETAIL” at the top left to view the full list of meters vis-

ible in the current zoom area. This function is designed 

for when multiple meters are installed in the same posi-

tion (e.g. an apartment block with 50 meters)

Meters which read correctly (without alarms) are dis-

played in green, while meters which have an active alarm 

are displayed in orange and with the warning sign (ex-

clamation point), while unread meters display in white.

There is an option to view all meters on the map at once: 

read and non-read, with active alarm or without alarm. 

The non-read meters only can also be viewed on the 

map.

This option eliminates meters that have just been read 

(correctly or with an alarm condition) from the map. To 

activate this option, move the cursor situated at the bot-

tom left-hand corner of the map to the left

To suspend the scan, click on “

SUSPEND” at the top right. 

A suspended reading can be resumed (“

RESUME SCAN”) 

or terminated (“

TERMINATE”).

Once a scan has been reset, you cannot resume it. You 

must launch a new scan. The status of readings from the 

previous scan is deleted. 

This means that if you have scanned 900 meters out of 

1000, the new scan will reset the readings counter; note, 

however, that the readings themselves are kept and not 

deleted. 

You can suspend a broadcast scan to make a single scan 

and then resume the previous broadcast scan.

Summary of Contents for Arrow Mobile Android

Page 1: ... EN_5000071C 04 2022 R3 Arrow Mobile Android Quick Start Guide USER INSTRUCTIONS EN Translation of the original instructions Please read this manual before using the device and keep it with the product ...

Page 2: ...of meters 4 3 2 Creating the database file CSV 5 4 Selecting the antenna 5 5 Scans 6 5 1 wMBus 169 scan 6 5 1 1 Broadcast scan 6 5 1 2 Single scan 7 5 2 Interrupted suspended scan 8 5 2 1 Intentional suspension 8 5 2 2 Accidental suspension 8 5 3 wMBus 868 scan 9 6 Detailed meter display 10 7 Managing and saving the read data 10 List of contents ...

Page 3: ...nge is affected by the surrounding environment and type of installation For example in the countryside the range may be as much as 1 5 2 km while in urban environments it may be 500 m or less depending the installation for models ARROWWAN 169 and ARROWWAN MVM 169 A transmitter in a wall niche is generally easier to scan wirelessly than one in a deep manhole Deep installations metal screening or eve...

Page 4: ...e Click on START NEW SCAN to proceed with the broad cast scan Click on START NEW SINGLE SCAN to scan a single ra dio entering the radio serial number or photographing its QR Code Click on LOAD DATA FROM EXTERNAL FILE to load the file of the meters on the map and any encryption keys Click on FIND METERS to view details of the detected meters and filter them by serial number Click on SCANS to view a...

Page 5: ...atitude and longi tude in decimal degrees e g 46 094576 or 13 292671 Below is a sample CSV file in MS Excel Note that the col umns have no headers The N O and P columns contain the serial numbers of the radios and their latitudes and longitudes These three columns are OBLIGATORY for the geograph ical location of the meters all other information is op tional 4 Selecting the antenna Before you can ma...

Page 6: ...es to map display mode When the view is zoomed out the meters display as clus ters i e as groups of meters to simplify the display If you zoom in you can view the details of the individual meters Click on a single meter to open a window with detailed information serial number meter address Click on DETAIL at the top left to view the full list of meters vis ible in the current zoom area This functi...

Page 7: ...to a limited extent In addition to broadcast mode you can also call an indi vidual radio This is useful when you want to scan a single radio with out scanning all the others in range as a test in the workshop for instance or if you have scanned 99 radios out of 100 and want to call the last one without creating collisions between the messages transmitted by radios which have already responded You ...

Page 8: ... readings the known_meters file 5 2 Interrupted suspended scan A scan can be interrupted for various reasons The oper ations to be carried out to resume the scan vary depend ing on the cause of the interruption 5 2 1 Intentional suspension Press the STOP key at the top right to suspend the scan When the scan is interrupted the STOP key is replaced by two other keys RESUME TURN to resume scanning fr...

Page 9: ...e page or on START NEW SCAN The terminal will start a broadcast read i e it will read all Maddalena radios whether in the database or not The protocol employed by Maddalena radios is a strict implementation of EN13757 and hence is able to receive any radio compliant with that standard even if it is not a Maddalena device The map and meters display is exactly the same as that for the 169 devices wi...

Page 10: ... to display a list of completed read operations These can be saved to a CSV file or deleted Click on DOWNLOAD to save a file for meters includ ed in the database filename known_meters_readout_x and a file for meters not included in the database file name unknown_meters_readout_x The readout files are saved to the Maddalena folder in the Downloads folder Each scan will generate its own readout file for in...

Page 11: ...11 ...

Page 12: ... S p A reserves the right to change its products at any time and without notice in order to improve them without affecting their essential features All illustrations and or photos included in this document may be shown with optional accessories that vary depending on the country where the device is used ...

Reviews: