Compliance Information

Countries approved for use, purchase and distribution:

Australia, Austria, Belgium, Bulgaria, Canada, Chile, China, Columbia, Croatia, Cyprus, Czech 
Republic, Denmark, Ecuador, Estonia, Finland, France, Germany, Greece, Honduras, Hungary, 
Iceland, Ireland, Israel, Japan, Latvia, Liechtenstein, Lithuania, Luxembourg, Malaysia, Malta, 
Mexico, New Zealand, Norway, Peru, Poland, Portugal, Romania, Saudi Arabia, Singapore, 
Slovakia, Slovenia, South Africa, South Korea, Spain, Sweden, Switzerland, Thailand, The 
Netherlands, Turkey, United Kingdom, United States, Venezuela, Vietnam

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) this device may not cause harmful interference, and (2) this device must accept 
any interference received, including interference that may cause undesired operation.
To satisfy FCC RF Exposure requirements for mobile and base station transmission devices, 
a separation distance of 20 cm or more should be maintained between the antenna of this 
device and persons during operation. To ensure compliance, operation at closer than this 
distance is not recommended. The antenna(s) used for this transmitter must not be co-located 
or operating in conjunction with any other antenna or transmitter.
This device complies with Industry Canada license-exempt RSS standard(s). Operation is 
subject to the following two conditions: (1) this device may not cause interference, and (2) 
this device must accept any interference, including interference that may cause undesired 
operation of the device. 

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils 
radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) 
l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout 
brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le 
fonctionnement.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna 
of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. 
To reduce potential radio interference to other users, the antenna type and its gain should 
be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that 
necessary for successful communication. 
Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut 
fonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé 
pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage 
radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain 
de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité 
nécessaire à l’établissement d’une communication satisfaisante.

Summary of Contents for Element CO2

Page 1: ...Product User Guide Element CO2 Wireless CO2 Humidity Temperature Data Logger ...

Page 2: ...at www madgetech com Quick Start Steps 3 Product Overview 4 Software Installation Guide 5 Activating Deploying the Data Logger 6 Channel Programming 6 Product Maintenance 7 RMA Instructions 7 Troubleshooting 8 Compliance Information 9 General Specifications 10 11 Table of Contents ...

Page 3: ...icking Start 7 To download data select the device in the list click the Stop icon and then click the Download icon A graph will automatically display the data 1 Install the MadgeTech 4 Software and USB Drivers onto a Windows PC 2 Confirm the data logger is not in wireless mode If wireless mode is on press and hold the Wireless button on the device for 5 seconds 3 Connect the data logger to the Win...

Page 4: ... information displayed on the LCD Screen Units Allows users to change displayed units of measurement to either Fahrenheit Celsius RH or ppm Wireless Push and hold this button for 5 seconds to activate or deactivate wireless communication Users have the ability to manually reset the statistics within the device to zero without needing to use the MadgeTech 4 Software Any data recorded up to that poi...

Page 5: ...cations from any internet enabled device Transmit real time data to the MadgeTech Cloud Services platform via the MadgeTech Data Logger Software running on a central PC or transmit directly to the MadgeTech Cloud without a PC using the MadgeTech RFC1000 Cloud Relay sold separately Sign up for a MadgeTech Cloud Services account at www madgetech com cloud Installing the USB Interface Driver USB Inte...

Page 6: ... transceiver that is on the same network is required to use the same channel If all of the devices are not on the same channel the devices will not communicate with one another MadgeTech wireless data loggers and RFC1000 wireless transceivers are programmed by default on channel 25 Changing the channel settings of the Element CO2 1 Switch the wireless mode to OFF by holding down the Wireless butto...

Page 7: ...l will be automatically sent when MadgeTech has received the RMA Product Maintenance Battery Replacement Materials U9VL J Battery 1 On the bottom of the data logger open the battery compartment by pulling in on the cover tab 2 Remove the battery by pulling it from the compartment 3 Install the new battery taking note of the polarity 4 Push the cover closed until it clicks Recalibration CO2 Zero Re...

Page 8: ...ooting wireless transceiver problems Check that the software properly recognizes the connected RFC1000 wireless transceiver If the wireless data logger is not appearing in the Connected Devices list it may be that the RFC1000 is not properly connected 1 In the MadgeTech 4 Software click the File button then click Options 2 In the Options window click Communications 3 The Detected Interfaces box wi...

Page 9: ...pt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes...

Page 10: ... RFC1000 CE RFC1000 IP69K or RFC1000 Cloud Relay Transmission Distance Unobstructed line of sight outdoors 2 000 feet max Typical urban environment indoors 500 feet max Wireless BATTERY WARNING BATTERY MAY LEAK FLAME OR EXPLODE IF DISASSEMBLED SHORTED CHARGED CONNECTED TOGETHER MIXED WITH USED OR OTHER BATTERIES EXPOSED TO FIRE OR HIGH TEMPERATURE DISCARD USED BATTERY PROMPTLY KEEP OUT OF REACH OF...

Page 11: ...ireless Operation RFC1000 wireless transceiver PC Compatibility MadgeTech 4 Windows 10 8 7 Vista Window XP with SP3 MadgeTech Cloud Services Compatible Yes Operating Environment 0 C to 55 C 32 F to 131 F 0 RH to 95 RH non condensing 13 77 PSIA to 100 PSIA Dimensions Data logger 3 0 in x 3 5 in x 0 95 in 76 2 mm x 88 9 mm x 24 1 mm Sensor 1 98 in x 1 98 in x 1 15 in 50 3 mm x 50 3 mm x 29 2 mm Cabl...

Page 12: ...Base online at www madgetech com kbase Contact our friendly Customer Support Team at 603 456 2011 or support madgetech com Need Help MadgeTech 4 Software Support Refer to the built in help section of the MadgeTech 4 Software Download the MadgeTech 4 Software Manual at www madgetech com mt4 software manual pdf MadgeTech Cloud Services Support Download the MadgeTech Cloud Services Software Manual at...

Reviews: