Product User Guide

5

Product Maintenance

Battery Replacement

Materials: 

ER1425S-HT Battery

1. 

Unscrew the bottom of the logger and remove the battery. 

2. 

Place the new battery into the logger. Note the polarity of the battery. 

3. 

Screw the cover back onto the logger. 

Recalibration 

The HiTemp140-M12 standard calibrations are two points at 50 

Ω

 and 150 

Ω

 and is 

verified at 100 

Ω

.

Prices and specifications subject to change. See MadgeTech’s terms and conditions at 

www.madgetech.com

To send devices to MadgeTech for calibration, service or repair, please use the MadgeTech RMA Process by visiting

www.madgetech.com

, then under the services tab, select RMA Process.

RMA Instructions

To send a device back in to MadgeTech, follow the instructions below to create an RMA 
(Return Merchandise Authorization) on the MadgeTech website:

1.

 Visit 

www.madgetech.com

, under the 

Services

 tab select 

RMA Process

.

2.

 When the web page opens, please sign in. If this is the first time, select 

Click here to 

register an account

 and create one. Once signed in, click on the 

Make New RMA

 

button and fill in all the blank fields. 

3.

 Complete the applicable fields on the form including customer Billing and Shipping 

information, even if they are the same. Please see the field explanation below for a more 
detailed description about questions asked in the Device Information section.

4.

 When all of the fields are complete, click 

Generate RMA

.

5.

 Print out the confirmation page that follows containing the RMA number and 

MadgeTech’s address for shipping. 

A Return Merchandise Authorization must be 

accompanied by a copy of the RMA paperwork and shipping is prepaid by the 
customer

. The RMA number should be clearly marked on the outside of the package.

6.

 Please ship the package via UPS, FedEx, TNT, or DHL to the address listed on the 

confirmation page. USPS will not ship MadgeTech data loggers.

7.

 A notification email will be automatically sent when MadgeTech has received the RMA.

Battery Warning

WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE, FORCE OVER 
DISCHARGE, CRUSH, PENETRATE, OR INCINERATE. BATTERY MAY LEAK OR EXPLODE IF HEATED ABOVE 140ºC (284ºF).

Specifications subject to change.

See MadgeTech’s terms and conditions at www.madgetech.com

Summary of Contents for HiTemp140-M12

Page 1: ...To view the full MadgeTech product line visit our website at www madgetech com Product User Guide HiTemp140 M12 HiTemp140 M12 High Temperature Data Logger with an M12 Probe Connector ...

Page 2: ...line visit our website at www madgetech com HiTemp140 M12 Data Logger Product Overview 2 Installation Guide 3 Device Operation 3 Wiring the Data Logger 4 Probe Connection 4 Product Maintenance 5 RMA Instructions 5 General Specifications 6 Table of Contents ...

Page 3: ...ote Specific M12 wiring configuration is required for compatibility see page 4 Submergibility The HiTemp140 M12 logger itself is rated IP40 and not submersible It will inherit the IP rating of the probe it is attached to allowing for potential submergibility depending upon the probe O Rings O ring maintenance is a key factor when properly caring for the HiTemp140 M12 The O rings ensure a tight sea...

Page 4: ...e for the data logging application and click Start Quick Start applies the most recent custom start options Batch Start is used for managing multiple loggers at once Real Time Start stores the dataset as it records while connected to the logger The status of the device will change to Running Waiting to Start or Waiting to Manual Start depending upon your start method Disconnect the data logger fro...

Page 5: ... attached to up to and including IP68 IP69K Probe Connection Connecting probes to the HiTemp140 M12 Materials 15 mm wrench Compatible Probe with M12 Connector 1 Connect the probe to the data logger using the wiring diagram above 2 Use a 15 mm hex wrench to tighten the threads and secure the probe to the data logger The HiTemp140 M12 is compatible with probes that have the wiring configuration as s...

Page 6: ...ce signed in click on the Make New RMA button and fill in all the blank fields 3 Complete the applicable fields on the form including customer Billing and Shipping information even if they are the same Please see the field explanation below for a more detailed description about questions asked in the Device Information section 4 When all of the fields are complete click Generate RMA 5 Print out th...

Page 7: ...ammed into the device to restrict access to configuration options Data may be read out without the password Memory Wrap Around Yes Battery Type 3 6V high temperature lithium battery included user replaceable Battery Life 1 year typical 1 minute reading rate Calibration Digital calibration through software Calibration Date Automatically recorded within device Data Format Date and time stamped C F R...

Page 8: ...MadgeTech Inc 6 Warner Road l Warner NH 03278 Phone 603 456 2011 l Fax 603 456 2012 www madgetech com l info madgetech com DOC 1312036 00 REV 2 01 22 2018 ...

Reviews: