RFC1000

• “This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.”

• “To satisfy FCC RF Exposure requirements for mobile and base station transmission devices, 
a separation distance of 20cm or more should be maintained between the antenna of
this device and persons during operation. To ensure compliance, operation at closer than
this distance is not recommended. The antenna(s) used for this transmitter must not be
co-located or operating in conjunction with any other antenna or transmitter.”

• “This device complies with Industry Canada license-exempt RSS standard(s). Operation is
subject to the following two conditions: (1) this device may not cause interference, and (2)
this device must accept any interference, including interference that may cause undesired
operation of the device.

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils 
radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) 
l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter 
tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre 
le fonctionnement.”

• “Under Industry Canada regulations, this radio transmitter may only operate using an
antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry
Canada. To reduce potential radio interference to other users, the antenna type and its gain
should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more
than that necessary for successful communication.

Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut 
fonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé 
pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage 
radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain 
de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité 
nécessaire à l’établissement d’une communication satisfaisante.”

Compliance Information

13

Summary of Contents for MadgeNET RFTemp2000A

Page 1: ...RFTemp2000A RFTemp2000A Wireless Temperature Data Logger Product User Guide...

Page 2: ...uctions 4 Product Maintenance 5 Recalibration 5 RMA Instructions 5 General Specifications 6 7 RFC1000 Transceiver Product Overview 9 Installation Guide 9 Mounting Instruction 10 Channel Programming 11...

Page 3: ...the Start icon 7 To download data select the device in the list click the Stop icon and then click the Download icon A graph will automatically display the data Quick Start Steps 1 Install the MadgeTe...

Page 4: ...evice status information displayed on the LCD Screen Units Allows user to change displayed units of measurement to either F or C Wireless Push and hold this button for 5 seconds to activate or deactiv...

Page 5: ...will occur from the drop down menus 4 If selecting to receive notifications by email or text message click Email settings and make sure the correct info has been entered Email and text message notifi...

Page 6: ...om of the logger snaps in place to use and mount the unit on a table top or horizontal surface The base can also securely snap to the backside of the logger for wall mounting if desired as shown below...

Page 7: ...y MadgeTech data logger a reminder is automatically displayed in the software when the device is due Countries approved for use purchase and distribution of the RFTemp2000A Australia Austria Belgium B...

Page 8: ...F For Software Date and time stamped C K F or R Time Accuracy 1 minute month Computer Interface USB to mini USB 250 000 baud for standalone operation or RFC1000 required for wireless operation Softwa...

Page 9: ...x indoors typical urban environment Wireless 7 Approvals US FCC CA IC CE South Korea KCC China CMIIT Japan LCIE General Specifications Continued This device complies with Part 15 of the FCC Rules Oper...

Page 10: ...Product User Guide RFC1000 Wireless Transceiver 8 Other models available RFC1000 CE Approved for European markets RFC1000 IP69K Splash Proof for harsh environments...

Page 11: ...ensing The RFC1000 is rated IP40 and is protected against solids that are greater than 1mm in size This device is not water resistant LEDs The red LED indicates that the device has power The green LED...

Page 12: ...ss performance both the RFC1000 and the MadgeTech data loggers should be mounted in the same orientation This usually means that the external antenna should be pointing straight up The antenna can piv...

Page 13: ...dgeTech data logger or RFC1000 that is on the same network is required to use the same channel If all of the devices are not on the same channel the devices will not communicate with one another The i...

Page 14: ...ere are walls obstacles corners that need to be maneuvered around set up additional RFC1000s as needed Step 3 Verify that the data loggers are in wireless transmission mode See Channel Programming ste...

Page 15: ...ada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit...

Page 16: ...ing in the Connected Devices list it may be that the RFC1000 is not properly connected 1 In the software click the File button then click Options 2 In the Options window click Communications 3 The Det...