background image

RFC1000

 

Product Overview

The RFC1000 is a high powered transceiver that has a substantially long transmission 
range, providing enhanced performance in occluded environments (ovens, refrigerators, 
etc.). The RFC1000 also features an external antenna, allowing more flexibility with 
mounting positions in both orientation and proximity to metal walls. The device may be 
used as a repeater, or directly plugged into the Windows PC.

 

Transmission Distance

The RFC1000 transmits to other RFC1000s up to 4000 feet maximum typical outdoors/
line of sight, 1000 feet maximum typical indoors/urban. The RFC1000 transmits to data 
loggers up to 2000 feet maximum typical outdoors/line of sight, 500 feet maximum typical 
indoors/urban. The RFC1000 can connect to a maximum of 64 data loggers. The RFC1000 
transmits on a frequency of 2.405 GHz - 2.475 GHz.

Operating Environment

The RFC1000 is rated for use in an environment with temperatures from -20 °C to 85 °C  
and a humidity range of 0 %RH to 95 %RH non-condensing. The RFC1000 is rated IP40 
and is protected against solids that are greater than 1mm in size. This device is not water 
resistant.

LEDs

The red LED indicates that the device has power. The green LED will blink when 
communicating with other devices.

Installation Guide

Installing the MadgeTech 4 Software

Insert the Data Logger Software Flash Drive into an open USB port 
on a Windows PC. If the autorun does not appear, locate the drive 
on the computer and double click on 

Autorun.exe

. Follow the 

instructions provided in the Installation Wizard. Software can also 
be downloaded from the MadgeTech website at the following 
link: 

www.madgetech.com/software-download.

 

1.

 Locate the 

Autorun.exe

 file on the Software Flash Drive.

2.

 Select “

Data Logger Software

” in the Installer Options window panel.

3.

 If the Windows PC doesn’t already have .NET 4.0 Framework, installation may  

be required. 

 

Note: To see if the .NET 4.0 Framework is installed, go to the Windows 

Control Panel

 and 

select 

Programs

. “

Microsoft .NET Framework 4.0

” would be listed as a Windows program. 

 

Select “

Install Data Logger Software

” if .NET framework is installed on the Windows 

PC, or if installing on a Windows 8 machine.

9

Summary of Contents for RFCurrent2000A

Page 1: ...RFCurrent2000A To view the full MadgeTech product line visit our website at www madgetech com RFCurrent2000A Wireless Current Data Logger Product User Guide...

Page 2: ...ional Features Operation 3 Mounting Instructions 4 Product Maintenance 5 Recalibration 5 RMA Instructions 5 General Specifications 6 7 RFC1000 Transceiver Product Overview 9 Installation Guide 9 Mount...

Page 3: ...Start icon 7 To download data select the device in the list click the Stop icon and then click the Download icon A graph will automatically display the data Quick Start Steps 1 Install the MadgeTech...

Page 4: ...C1000 wireless transceiver to transmit data back to a central PC The RFCurrent2000A transmits up to 500 ft line of sight to the RFC1000 transceiver Multiple RFC1000 s can be used as repeaters and tran...

Page 5: ...ave met before notifications occur and select which notifications will occur from the drop down menus 4 If selecting to receive notifications by email or text message click Email settings and make sur...

Page 6: ...ttom of the logger snaps in place to use and mount the unit on a table top or horizontal surface The base can also securely snap to the backside of the logger for wall mounting if desired as shown bel...

Page 7: ...he blank fields 3 Complete the applicable fields on the form including customer Billing and Shipping information even if they are the same Please see the field explanation below for a more detailed de...

Page 8: ...Date Automatically recorded through the device Battery Type Ultralife 9V Lithium included user replaceable Battery Life Approximately 4 years typical for 15 minute reading rate Data Format A mA A Time...

Page 9: ...ss Battery Warning WARNING BATTERY MAY LEAK FLAME OR EXPLODE IF DISASSEMBLED SHORTED CHARGED CONNECTED TOGETHER MIXED WITH USED OR OTHER BATTERIES AND OR EXPOSED TO FIRE HIGH TEMPERATURE DISCARD USED...

Page 10: ...Product User Guide RFC1000 Wireless Transceiver 8 Other models available RFC1000 CE Approved for European markets RFC1000 IP69K Splash Proof for harsh environments...

Page 11: ...condensing The RFC1000 is rated IP40 and is protected against solids that are greater than 1mm in size This device is not water resistant LEDs The red LED indicates that the device has power The green...

Page 12: ...ireless performance both the RFC1000 and the data loggers should be mounted in the same orientation This usually means that the external antenna should be pointing straight up The antenna can pivot to...

Page 13: ...ta logger or RFC1000 that is on the same network is required to use the same channel If all of the devices are not on the same channel the devices will not communicate with one another The images belo...

Page 14: ...or there are walls obstacles corners that need to be maneuvered around set up additional RFC1000s as needed Step 3 Verify that the data loggers are in wireless transmission mode See Channel Programmin...

Page 15: ...ada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit...

Page 16: ...oftware click the File button then click Options 2 In the Options window click Communications 3 The Detected Interfaces box will list all of the available communication interfaces If the RFC1000 is li...

Reviews: