1.

 

Install the MadgeTech 4 Software and USB Drivers onto a Windows PC. 

2.

 

The RFC1000 interface device comes with a USB cable. Plug one end of the cable into 

an available USB port on the PC and plug the opposite end of the cable into the  
communication port on the RFC1000.

3.

 

Push and hold the wireless button on the RFCurrent2000A for 5 seconds to activate 

wireless communication. The display will confirm “Wireless: ON” and the blue LED will 
blink every 15 seconds.

4.

 

Launch the MadgeTech 4 Software. All active MadgeTech Data Loggers that are within 

range will automatically appear in the connected devices window. Each data logger in 
the list can be identified by serial number (printed on the exterior of the logger).

5.

 

To claim a device, select the desired data logger in the list and click the 

Claim

 icon.

6.

 

Select the start method, reading rate and any other parameters appropriate for the 

desired data logging application. Once configured, deploy the data logger by clicking 
the 

Start

 icon.

7.

 

To download data, select the device in the list, click the 

Stop

 icon, and then click the 

Download

 icon. A graph will automatically display the data.

Quick Start Steps

 

1.

 

Install the MadgeTech 4 Software and USB Drivers onto a Windows PC. 

2.

 

Before plugging the data logger in the computer, make sure the wireless setting on  

the device is set to “Wireless: OFF”. If wireless mode is on, press and hold the Wireless  
button on the device for 5 seconds. 

3.

 

The RFCurrent2000A comes with a USB cable. Plug one end of the cable into an  

available USB port on the PC and plug the opposite end of the cable into the  
communication port on the RFCurrent2000A.

4.

 

Launch the Data Logger Software. The RFCurrent2000A will appear in the connected 

devices window indicating the device has been recognized.

5.

 

Select the start method, reading rate and any other parameters appropriate for the  

desired data logging application. Once configured, deploy the data logger by clicking 
the 

Start

 icon.

6.

 

To download data, select the device in the list, click the 

Stop

 icon, and then click the 

Download

 icon. A graph will automatically display the data.

Product Operation (Plugged In)

Product Operation (Wireless)

Summary of Contents for RFCurrent2000A

Page 1: ...RFCurrent2000A To view the full MadgeTech product line visit our website at www madgetech com RFCurrent2000A Wireless Current Data Logger Product User Guide...

Page 2: ...ional Features Operation 3 Mounting Instructions 4 Product Maintenance 5 Recalibration 5 RMA Instructions 5 General Specifications 6 7 RFC1000 Transceiver Product Overview 9 Installation Guide 9 Mount...

Page 3: ...Start icon 7 To download data select the device in the list click the Stop icon and then click the Download icon A graph will automatically display the data Quick Start Steps 1 Install the MadgeTech...

Page 4: ...C1000 wireless transceiver to transmit data back to a central PC The RFCurrent2000A transmits up to 500 ft line of sight to the RFC1000 transceiver Multiple RFC1000 s can be used as repeaters and tran...

Page 5: ...ave met before notifications occur and select which notifications will occur from the drop down menus 4 If selecting to receive notifications by email or text message click Email settings and make sur...

Page 6: ...ttom of the logger snaps in place to use and mount the unit on a table top or horizontal surface The base can also securely snap to the backside of the logger for wall mounting if desired as shown bel...

Page 7: ...he blank fields 3 Complete the applicable fields on the form including customer Billing and Shipping information even if they are the same Please see the field explanation below for a more detailed de...

Page 8: ...Date Automatically recorded through the device Battery Type Ultralife 9V Lithium included user replaceable Battery Life Approximately 4 years typical for 15 minute reading rate Data Format A mA A Time...

Page 9: ...ss Battery Warning WARNING BATTERY MAY LEAK FLAME OR EXPLODE IF DISASSEMBLED SHORTED CHARGED CONNECTED TOGETHER MIXED WITH USED OR OTHER BATTERIES AND OR EXPOSED TO FIRE HIGH TEMPERATURE DISCARD USED...

Page 10: ...Product User Guide RFC1000 Wireless Transceiver 8 Other models available RFC1000 CE Approved for European markets RFC1000 IP69K Splash Proof for harsh environments...

Page 11: ...condensing The RFC1000 is rated IP40 and is protected against solids that are greater than 1mm in size This device is not water resistant LEDs The red LED indicates that the device has power The green...

Page 12: ...ireless performance both the RFC1000 and the data loggers should be mounted in the same orientation This usually means that the external antenna should be pointing straight up The antenna can pivot to...

Page 13: ...ta logger or RFC1000 that is on the same network is required to use the same channel If all of the devices are not on the same channel the devices will not communicate with one another The images belo...

Page 14: ...or there are walls obstacles corners that need to be maneuvered around set up additional RFC1000s as needed Step 3 Verify that the data loggers are in wireless transmission mode See Channel Programmin...

Page 15: ...ada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit...

Page 16: ...oftware click the File button then click Options 2 In the Options window click Communications 3 The Detected Interfaces box will list all of the available communication interfaces If the RFC1000 is li...

Reviews: