1

1.

 

Install the MadgeTech 4 Software and USB Drivers onto a Windows PC. 

2.

 

The RFC1000 interface device comes with a USB cable. Plug one end of the cable into 

an available USB port on the PC and plug the opposite end of the cable into the  
communication port on the RFC1000.

3.

 

Push and hold the wireless button on the RFPulse2000A for 5 seconds to activate  

wireless communication. The display will confirm “Wireless: ON” and the blue LED  
will blink every 15 seconds.

4.

 

Launch the MadgeTech 4 Software. All active MadgeTech Data Loggers that are within 

range will automatically appear in the connected devices window. Each data logger in 
the list can be identified by serial number (printed on the exterior of the logger).

5.

 

To claim a device, select the desired data logger in the list and click the 

Claim

 icon.

6.

 

Select the start method, reading rate and any other parameters appropriate for the 

desired data logging application. Once configured, deploy the data logger by clicking 
the 

Start

 icon.

7.

 

To download data, select the device in the list, click the 

Stop

 icon, and then click the 

Download

 icon. A graph will automatically display the data.

Quick Start Steps

 

1.

 

Install the MadgeTech 4 Software and USB Drivers onto a Windows PC. 

2.

 

Before plugging the data logger in the computer, make sure the wireless setting on  

the device is set to “Wireless: OFF”. If wireless mode is on, press and hold the Wireless  
button on the device for 5 seconds. 

3.

 

The RFPulse2000A comes with a USB cable. Plug one end of the cable into an available 

USB port on the PC and plug the opposite end of the cable into the communication 
port on the RFPulse2000A.

4.

 

Launch the MadgeTech 4 Software. The RFPulse2000A will appear in the connected 

devices window indicating the device has been recognized.

5.

 

Select the start method, reading rate and any other parameters appropriate for the  

desired data logging application. Once configured, deploy the data logger by clicking 
the 

Start

 icon.

6.

 

To download data, select the device in the list, click the 

Stop

 icon, and then click the 

Download

 icon. A graph will automatically display the data.

Product Operation (Plugged In)

Product Operation (Wireless)

 

 

 

Distributor: LoggerShop Technologies | Dorset 

Tel: +44 (0)845 520 0202 Fax: +44 (0)845 520 0203 | Email: sales@loggershop.co.uk | www.loggershop.co.uk

Summary of Contents for RFPulse2000A

Page 1: ...lse2000A RFPulse2000A Wireless Pulse Data Logger Product User Guide Distributor LoggerShop Technologies Dorset Tel 44 0 845 520 0202 Fax 44 0 845 520 0203 Email sales loggershop co uk www loggershop c...

Page 2: ...ions 6 7 RFC1000 Transceiver Product Overview 9 Installation Guide 9 Mounting Instruction 10 Channel Programming 11 Deployment Activation 12 General Specifications 12 Compliance Information 13 Trouble...

Page 3: ...the Stop icon and then click the Download icon A graph will automatically display the data Quick Start Steps 1 Install the MadgeTech 4 Software and USB Drivers onto a Windows PC 2 Before plugging the...

Page 4: ...nd device status information displayed on the LCD Screen Units Allows user to change displayed units of measure to pulses per sec min hour day total number of pulses Wireless Push and hold this button...

Page 5: ...ications by email or text message click Email settings and make sure the correct info has been entered Email and text message notifications will not be received if settings are incorrect 5 Click OK Th...

Page 6: ...as shown below There are two holes in the base to allow for screws for mounting Mounting Instructions 4 Still need help For more troubleshooting tips and information refer to the built in help sectio...

Page 7: ...mpartment by pulling in on the cover tab 2 Remove the battery by pulling it from the compartment 3 Install the new battery taking note of the polarity 4 Push the cover closed until it clicks 5 Distrib...

Page 8: ...S alarms Alarm Delay A cumulative alarm delay may be set in which the device will activate the alarm via LED only when the device has recorded a user specified time duration of data Audible Alarm Func...

Page 9: ...vironment RFC1000 CE 2 500 max outdoors line of sight unobstructed 700 max indoors typical urban environment RFC1000 IP69K 4 000 max outdoors line of sight unobstructed 1 000 max indoors typical urban...

Page 10: ...Other models available RFC1000 CE Approved for European markets RFC1000 IP69K Splash Proof for harsh environments Distributor LoggerShop Technologies Dorset Tel 44 0 845 520 0202 Fax 44 0 845 520 0203...

Page 11: ...re greater than 1mm in size This device is not water resistant LEDs The red LED indicates that the device has power The green LED will blink when communicating with other MadgeTech devices 9 Installat...

Page 12: ...be mounted in the same orientation This usually means that the external antenna should be pointing straight up The antenna can pivot to accommodate either a wall mount or a desk mount 10 Distributor...

Page 13: ...to use the same channel If all of the devices are not on the same channel the devices will not communicate with one another The images below show the orientations available of the switches for each ch...

Page 14: ...t indoors or 4000 feet outdoors or there are walls obstacles corners that need to be maneuvered around set up additional RFC1000s as needed Step 3 Verify that the data loggers are in wireless transmis...

Page 15: ...est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage e...

Page 16: ...utton then click Options 2 In the Options window click Communications 3 The Detected Interfaces box will list all of the available communication interfaces If the RFC1000 is listed here then the softw...

Reviews: