background image

Product User Guide

Reading Rate 1 reading every second up to 1 reading every 24 hours

Memory 16,128 readings

LED Functionality

• Green LED blinks every 5 seconds to indicate unit is logging
• Blue LED blinks every 15 seconds to indicate unit is in wireless mode
• Red LED blinks every 1 second to indicate alarm condition

Wrap Around Yes

Start Modes Immediate Start & Delay Start

Battery Type Ultralife 9V lithium battery included; user replaceable

Battery  Life   5 years typical at 10 minute reading rate

Display Details Displays Pulse/Interval Count & Total Count

Time Accuracy  ±1 minute/month

Computer Interface

USB to mini USB, 250,000 baud for standalone operation or RFC1000 
required for wireless operation

Software XP SP3/Vista/Windows 7/Windows 8 (MadgeTech 4 only)

Operating  

Environment

-20°C to +60°C (-4°F to +140°F); 0 to 95% RH non-condensing

Dimensions 3.5” x 3.0” x 0.95” (88.9mm x 76.2mm x 24.1mm) - Data logger only

Weight 4.1 oz (0.2563 lbs)

Enclosure Material ABS Plastic

Alarm

User configurable audible, on-screen, email and text (SMS) alarms.

Alarm Delay: A cumulative alarm delay may be set in which the device 
will activate the alarm (via LED) only when the device has recorded a 
user specified time duration of data.

Audible Alarm 

Functionality

1 Beep per second for reading alarm above/below threshold

Overload Protection ±30 Volts (V) for 2 seconds

Approval US (FCC), CA (IC), CE, South Korea (KCC)

RFPulse2000A General Specifications

6

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may 

not cause harmful interference, and (2) this device must accept any interference received, including interference that may 

cause undesired operation.

To satisfy FCC RF Exposure requirements for mobile and base station transmission devices, a separation distance of 20 cm 

or more should be maintained between the antenna of this device and persons during operation. To ensure compliance, 

operation at closer than this distance is not recommended. The antenna(s) used for this transmitter must not be co-located 

or operating in conjunction with any other antenna or transmitter.

 

 

 

Distributor: LoggerShop Technologies | Dorset 

Tel: +44 (0)845 520 0202 Fax: +44 (0)845 520 0203 | Email: sales@loggershop.co.uk | www.loggershop.co.uk

Summary of Contents for RFPulse2000A

Page 1: ...lse2000A RFPulse2000A Wireless Pulse Data Logger Product User Guide Distributor LoggerShop Technologies Dorset Tel 44 0 845 520 0202 Fax 44 0 845 520 0203 Email sales loggershop co uk www loggershop c...

Page 2: ...ions 6 7 RFC1000 Transceiver Product Overview 9 Installation Guide 9 Mounting Instruction 10 Channel Programming 11 Deployment Activation 12 General Specifications 12 Compliance Information 13 Trouble...

Page 3: ...the Stop icon and then click the Download icon A graph will automatically display the data Quick Start Steps 1 Install the MadgeTech 4 Software and USB Drivers onto a Windows PC 2 Before plugging the...

Page 4: ...nd device status information displayed on the LCD Screen Units Allows user to change displayed units of measure to pulses per sec min hour day total number of pulses Wireless Push and hold this button...

Page 5: ...ications by email or text message click Email settings and make sure the correct info has been entered Email and text message notifications will not be received if settings are incorrect 5 Click OK Th...

Page 6: ...as shown below There are two holes in the base to allow for screws for mounting Mounting Instructions 4 Still need help For more troubleshooting tips and information refer to the built in help sectio...

Page 7: ...mpartment by pulling in on the cover tab 2 Remove the battery by pulling it from the compartment 3 Install the new battery taking note of the polarity 4 Push the cover closed until it clicks 5 Distrib...

Page 8: ...S alarms Alarm Delay A cumulative alarm delay may be set in which the device will activate the alarm via LED only when the device has recorded a user specified time duration of data Audible Alarm Func...

Page 9: ...vironment RFC1000 CE 2 500 max outdoors line of sight unobstructed 700 max indoors typical urban environment RFC1000 IP69K 4 000 max outdoors line of sight unobstructed 1 000 max indoors typical urban...

Page 10: ...Other models available RFC1000 CE Approved for European markets RFC1000 IP69K Splash Proof for harsh environments Distributor LoggerShop Technologies Dorset Tel 44 0 845 520 0202 Fax 44 0 845 520 0203...

Page 11: ...re greater than 1mm in size This device is not water resistant LEDs The red LED indicates that the device has power The green LED will blink when communicating with other MadgeTech devices 9 Installat...

Page 12: ...be mounted in the same orientation This usually means that the external antenna should be pointing straight up The antenna can pivot to accommodate either a wall mount or a desk mount 10 Distributor...

Page 13: ...to use the same channel If all of the devices are not on the same channel the devices will not communicate with one another The images below show the orientations available of the switches for each ch...

Page 14: ...t indoors or 4000 feet outdoors or there are walls obstacles corners that need to be maneuvered around set up additional RFC1000s as needed Step 3 Verify that the data loggers are in wireless transmis...

Page 15: ...est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage e...

Page 16: ...utton then click Options 2 In the Options window click Communications 3 The Detected Interfaces box will list all of the available communication interfaces If the RFC1000 is listed here then the softw...

Reviews: