EN
4
English
End-Of-Life
This electrical device and its accessories need to be disposed of
properly. Do not throw the device into normal trash or household
waste. Please recycle packaging material whenever possible.
Usage
In general, this device is designed to receive DMX512 data over Ethernet
(Art-Net) or USB and distribute it over XLR. It is a hardware interface to be
connected towards various types of controllable lights or lighting controllers.
Do not use the interface for any other, deviating purpose.
The device can be connected to and disconnected from the PC during use and
without a reboot (Hot Swapping & Plug and Play). Multiple interfaces can be
used at the same time.
Technical Specifications
THE DEVICE REQUIRES AC 100 V – 240 V TO WORK. DO NOT USE ANY
OTHER VOLTAGE BECAUSE IT CAN DAMAGE THE DEVICE.
Power supply:
Power consumption:
DMX512 (OUT):
DMX512 (IN):
DMX512 ports (OUT):
DMX512 ports (IN):
Ethernet (Art-Net):
USB port:
Case:
Size:
Dimensions (body only):
Dimensions (total):
Dimensions (LUNA 16):
Weight:
Temperature range:
Relative humidity:
AC
100
–
240
V,
50 – 60
Hz,
0.4
A
max.,
IEC
C14
inlet
< 5 W during normal operation
4x / 8x / 16x 512 DMX channels output
1x 512 DMX channels input
5-pin, XLR, female, NEUTRIK
5-pin, XLR, male, NEUTRIK
RJ45,
10/100 MBit/s, Auto MDI-X, NEUTRIK etherCON
(compatible with 1 GBit/s)
USB 2.0, type B plug
Metal enclosure, IP20
19
″
x 1U (LUNA 4 / LUNA 8) | 19
″
x 2U (LUNA 16)
76 mm x 440 mm x 44 mm (length x width x height)
76 mm x 482.6 mm x 44 mm (length x width x height)
76 mm x 482.6 mm x 88 mm (length x width x height)
1.3 kg (LUNA 4)
|
1.4 kg (LUNA 8)
|
2.0 kg (LUNA 16)
-10 °C to 60 °C (Operating)
|
-20 °C to 70 °C (Storage)
20 % to 80 %, non-condensing (Operating / Storage)