EN
4
English
End-Of-Life
This electrical device and its accessories need to be disposed of
properly. Do not throw the device into normal trash or household
waste. Please recycle packaging material whenever possible.
Usage
In general, this device is designed to be operated as a hardware control
interface to be connected towards various types of controllable lights / lighting
controllers via DMX512 by using USB or Art-Net / Streaming ACN over Ethernet.
Do not use the interface for any other, deviating purpose.
The device can be connected to and disconnected from USB or Ethernet
network during use and without a reboot (Hot Swapping & Plug and Play).
Multiple interfaces can be used at the same time.
Technical Specifications
Supply of power:
Power supply:
(As provided / external)
Power consumption:
DMX512:
DMX512 ports:
Ethernet:
USB port:
Case:
Dimensions:
Weight:
Temperature range:
Relative humidity:
DC 5 V – 24 V, connection via 2-pin screw terminal
(external power supply included) or via 5 V USB
AC Input: 110 – 240 V, 50/60 Hz, 0.6 A;
DC Output: (3 V) / (4.5) / 5 V / 6 V / 7.5 V / 9 V / 12 V,
2.0 A max.
< 1.5 W during normal operation (300 mA max.)
2x 512 DMX channels, input and/or output
2x ports (via 2x 3-pin, pluggable screw terminals)
2x RJ45, Auto MDI-X, 10/100 MBit/s (compatible with
1 GBit/s)
USB 2.0, type B plug
Non-conductive, IP20, UL94 V-0 flammability rating,
designed for 35 mm DIN-rails or wall mounting
92 mm x 70 mm x 45 mm (length x width x height)
108 g | 125 g incl. screw terminals and wall mounts
-10 °C to 70 °C (Operating) | -20 °C to 85 °C (Storage)
5 % to 80 %, non-condensing (Operating / Storage)
WHEN CONNECTING TO USB, ALWAYS USE AN ACTIVE USB 2.0
PORT OR A USB 2.0 HUB WITH ITS OWN POWER SUPPLY.