background image

-13-

JETS

Turn the NoPipe™ Jets on by pressing the “Jets” button. To turn the NoPipe Jets off press the “Jets”
button again.

NOTE:

The NoPipe Jets will automatically shut off 45 minutes after continuous operation. You may

reactivate the NoPipe Jets by pressing the “Jets” button. The jets can not be activated during the fill
cycle.

WARNING:

DO NOT ATTEMPT TO OPERATE JETS WITHOUT WATER.

SPRAYER

To activate the hand held sprayer (11), pull the sprayer from the receptacle, press the “Sprayer” button
located on the Technicians Control Panel and depress the thumb control on the sprayer handle. Release
the thumb control button to stop water flow.

IMPORTANT: When sprayer is not in use, always press

the “Sprayer” button and the thumb control to relieve water pressure to the sprayer head.

NOTE:

The sprayer has a built in timer and will be available for use for one (1) minute after you press

the “Sprayer” button. In order to use sprayer for a longer period of time simply press “Sprayer” button
again.

CLEAN

WARNING:

It is extremely important to follow the cleaning instructions provided in this manual.

Failure to clean the pedicure spa adequately can result in serious health issues for your clients as well
as the nail technician. Failing to clean your pedicure spa may also cause it to work improperly. Regular
cleaning will keep your pedicure spa in good working condition. Always consult your local and state
codes regarding pedicure cleaning and disinfecting for further requirements.

To use the Clean cycle on the Maestro Pedicure Spa close the drain by turning drain handle (13) count-
er-clockwise. Press “Clean” button on the Technician Control Panel. The basin will start filling with water.
The water will stop automatically when it reaches the required level. Add disinfecting solution as out-
lined in Cleaning Instructions. Press “Jets” button again to activate the NoPipe Jets. The Clean cycle
will run for 10 minutes. After the cycle is completed the timer will turn the NoPipe Jets off. Drain your
spa by turning the drain handle (13) clockwise, spray the basin using the hand-held sprayer and wipe it
down with the clean cloth.

NOTE:
Since no one should ever be seated in the chair during a Clean cycle, the seat will not operate
during the Clean cycle.

You are required to check with your state board for mandatory cleaning and disinfecting require-
ments and procedures.

MAESTRO

®

PEDICURE SPA

Summary of Contents for PEDICURE SPA

Page 1: ...MAESTRO PEDICURE SPA OWNER S MANUAL C...

Page 2: ...rounding and GFCI Requirements 6 Hot Cold Water Supply and Drain 6 7 Features of the Maestro Pedicure Spa 8 9 Instructions Pertaining to a Risk of Fire Electric Shock or Injury to Persons 10 Operating...

Page 3: ...300 pounds Never bring or operate any electrical device in or near the Maestro Always enter and exit the Maestro very slowly and carefully The seat has been designed to swivel in order to help enteri...

Page 4: ...efer to Plumbing Rough in drawing available at ContinuumFootspas com See Owners Manual for complete installation instructions Massage Exclusive Acoustic Therapy relaxation system Built in MP3 player H...

Page 5: ...Limited Warranty to be valid your Maestro Pedicure Spa must be installed by a licensed professional in accor dance with Continuum Footspas installation instructions EXCLUDED FROM LIMITED WARRANTY 1 U...

Page 6: ...nty the warranty registration card MUST be filled out completely and returned to Continuum Footspas within 30 days of original installation IN ORDER FOR THE LIMITED WARRANTY TO BE VALID THE MAESTRO PE...

Page 7: ...Location and Securing to Floor The Maestro Pedicure Spa must be located on a level floor that is capable of supporting both the Pedicure Spa and a client Important The Maestro Pedicure Spa MUST be anc...

Page 8: ...INJURY TO PERSONS All servicing of this unit must be performed by authorized service personnel only DO NOT operate this appliance if it has a damaged cord or plug if it is not working properly Keep co...

Page 9: ...located near the power supply box UNLOCK THE QUICK DISCONNECT FITTING NEXT TO THE HANGING TAG LEAVE ALL OTHER QUICK DISCONNECT FITTINGS IN PLACE Step 4 Utilizing a phillips head screwdriver carefully...

Page 10: ...of the Maestro Pedicure Spa 1 Adjustable headrest 2 Chair control keypad 3 Acoustic Therapy Control Keypad 4 Headphone holder 5 Beverage holder 6 MP3 jack 7 Pivoting leg supports 8 Basin overflow 9 S...

Page 11: ...9 MAESTRO PEDICURE SPA 11 Sprayer 12 Technician s Control Keypad 13 Drain Handle 14 Temperature Control Handle 15 NoPipe Jets 16 Drain pop up 17 Removable foot massage rollers...

Page 12: ...round fault circuit interrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push...

Page 13: ...problems including decreased feeling or circulation to the feet Use of this product should be pleasant and comfortable Should pain or discomfort result discontinue use and consult your physician WARNI...

Page 14: ...ure for comfort and safety Adjust water temperature utiliz ing temperature control handle 14 as needed Once desired water temperature is set close the drain by turning drain handle 13 counter clockwis...

Page 15: ...to clean the pedicure spa adequately can result in serious health issues for your clients as well as the nail technician Failing to clean your pedicure spa may also cause it to work improperly Regula...

Page 16: ...drain pump LEG SUPPORTS 7 The Maestro s dual and independent leg supports pivot upward to support the entire leg not just the foot Feet are perfectly positioned for massage and pedicure treatments To...

Page 17: ...st has a built in counterweight that keeps it in position To adjust simply move the head rest up or down until a comfortable position is reached HEADPHONES 4 Headphones supplied may be used to enhance...

Page 18: ...the pedicure is completed press and hold the Exit button for two 2 seconds The chair will then return to it s Home position After the chair stops the locking mechanism will disengage and the chair ca...

Page 19: ...button on control keypad 3 Headphones Press and hold appropriate button on control keypad 3 Notes and Comments on the Built in MP3 Player Tracks may be changed at any time If the play pause button is...

Page 20: ...Drain all water from the basin 2 Scrub all visible residue from the inside walls of the basin with a brush or liquid soap and water Use a clean and disinfected brush with a handle Brushes must be clea...

Page 21: ...in 5 Refill the basin with clean water and circulate the correct amount read the label for mixing instructions of the EPA registered Hospital liquid disinfectant through the basin for 10 minutes Make...

Page 22: ...rst cleaned of large amounts of residue iii Are used exactly as described by the manufacturer s instructions C All bottles and containers other than the original manufacturers container containing any...

Page 23: ...outlines by your state board one may chose to scrub the basin as well Simply use any nylon scouring pad ie Scotch Bright together with a good cleaning powder ie Bar Keeper s Friend This additional cl...

Page 24: ...e Tech Keypad Depress the button on the handheld sprayer and gently shake any excess water into the basin Rather than return it to the saddle you may choose to place the sprayer hose between the leg s...

Page 25: ...MAESTRO PEDICURE SPA NOTES...

Page 26: ...lient Time Staff Date m d yr _______________________________ Station __________ Serial ______________ Service No 1 2 3 4 5 6 7 8 9 10 Client Time Staff Date m d yr _______________________________ Serv...