-34-
Operating mode
Remaining runtime /
s
Display remaining runtime
U
O
/ V
Setting
wheel
-
illumination
Continuous operation unlimited
0
Blue (BU), permanent
Overload mode
(motor is running)
< 160
1.5
1 x red pulse (RD)
< 80
2.5
< 40
3
2 x red pulse (RD)
< 20
4
< 10
4.5
3 x red pulse (RD)
< 5
5
Red (RD), permanent
Switch-off
0
5
Table 4: Correlation between the remaining runtime and the associated output variables
6
Service and maintenance
Danger
Pull the power plug during all service work.
MAFELL machines are designed to be low in maintenance.
Replace the carbon brushes at the latest after 125 - 150 operating hours. The spare parts can be referenced in
chapter 9.
The ball bearings used are greased for life. When the machine has been in operation for a longer period of time,
we recommend to hand the machine in at an authorised MAFELL customer service shop for inspection.
Have your power tool serviced by a qualified repair person using only identical replacement parts.
This
will ensure that the safety of the power tool is maintained.
6.1
Storage
If the milling motor is out of service for a lengthy period of time, it should be thoroughly cleaned. Spray bright
metal parts with a rust inhibitor. Close the portal connector with the supplied covering cap Z (Fig. 3).