background image

M

M

AG

AG

 AR200U Quick User Manual

(1) Cable Wire assignment

The AR200U has two main cables: Signal cable and power cable. Cable wiring 

description is shown in the tables below:

(2) Interface selection:

Yellow and pink wire is used to select Wiegand output format on Green and White wire. 

AR200U’s wiegand output format must match controller’s input format in order to capture 

correct card number. Please also ensure that AR200U’s GND is connected to controller’s 

GND to achieve “common GND”. Otherwise Wiegand data will not be received by 

controller.

(3) LED Indicators

The AR200U has status and tuning LEDs (see figure below). 

•    Blue LED is on whenever the AR200U is powered and ready to read the card

•    Red LED blinks once when the good read has been achieved. 

•    Green LED is only used during the firmware download.

•    Auto tuning LED indicate frequency shift position. The ideal 4 to 5 LED turned    

     red color.

Access controller

Data 0

Data 1

GND

Wiegand
port

Green

White

Black (GND)

Yellow

Pink

Select Wiegand
output format

Thick Black

Thick White

Signal

Power

Common 

GND

PS20A 

19.2V

regulator and filter

AC-AC 24V

Power adapter 

Main AC 
power supply

PD24/7.5

Data and
DC surge 
protector

TPLAN

Data surge 
protector

PSP24

DC surge 
protector

+19.2 V

GND

INSIDE GOOSENECK

(Safely protected by surge protector at end point. All surge protector MUST be connect to EARTH)

CABLE TRAVELING INSIDE PIPING

(Subject to lightning surge induction)

INSIDE GUARD HOUSE
(Safely protected by surge protector at end point. All surge protector MUST be connect to EARTH)

Induced surge will travel both way via 
cable to damage device at end point.

AR200U

RFID Mid range reader

Thin Black

Blue

Blue

Red

Red

Green

Green

LED color:

Auto tuning LED

M

AG

M

AG

RFID Reader

Status LED

M

AG

M

AG

RFID Reader