Starting at basic view we must hold the button
ENTER
two seconds long:
Basic view goes to the frame 1 where we use button
▲
till we get to the frame 2. Short click on the
ENTER
and we are in
the frame 2.1. One more time click on the
ENTER
and we get to the frame 2.1.1. Using buttons
▲
or
we can choose
required parameter:
Frame 2.1.1 we can leave by double click of the
►
( ESC ).
Combustion upper temperature
– increase over of this value limits speed of
the fan. It provides chimney protection.
130 - 280°C
Combustion lower temperature
– decrease under of this value activates
boiler status
END
– fuel burnout. It keeps the embers waiting.
50 - 130°C
Main fan power change. For example: value -3 decreases fan speed in 30%
-3, -2, ... 2, 3
Fan minimal speed. This value is limit for speed decrease of the fan after
reaching requested boiler temperature.
0
– 70%
LCD display brightness
0 - 128
Roling of the values in user depiction on the basic view of the display.
yes / no
Time to display help of five arrrov button in frame 2.1.1
0
– 10 s
Ventilation in combustion chamber
– this time interval of the 100%
fan speed is switched every 60 seconds after overrun the required
boiler temperature
0
– 300 s
Time to reach END status after decreasing the combustion
temperature below
end
value
0
– 60 min
Temperature scale set up.
°C ( Celsius ) / °F ( Fahrenheit )
Automatic change of winter and summer time.
yes / no
User Parameter Setup
AK6000.X