User's manual 

 Version 1.0                                                  March 2021                                                      1/17

 

 

 

 

 

Aethalometer

®

  

High Altitude Booster Pump  

User’s Manual

 

 

 

Version 1.0 

 

March 2021 

 

 

Summary of Contents for Aerosol Aethalometer AETH-HA-PUMP

Page 1: ...______________________________________________________________________________________________ User s manual Version 1 0 March 2021 1 17 Aethalometer High Altitude Booster Pump User s Manual Version 1...

Page 2: ...contents of this manual with their own names trademarks and logos for branding purposes and for the distribution of the Magee Scientific Aethalometer High Altitude Booster Pump The text may not be mo...

Page 3: ...cking the equipment 5 1 2 Intended use and description of the equipment 6 1 3 Technical specification 7 2 IDENTIFICATION SAFETY NOTES and LABELS 8 2 1 Equipment identification label 8 2 2 Safety notes...

Page 4: ...provides a constant sample flow rate of 5 SLPM stabilized by the internal mass flow sensors from sea level to an altitude of approximately 3000 m At higher altitudes while the analytical optics of the...

Page 5: ...de Booster Pump AETH HA PUMP are as follows External AC DC power supply VES150PS12 Control cable HAP 1 99 004 Power supply cord B88F306 EU M6115 US M6117 China M5118 UK Black conductive sample line tu...

Page 6: ...culation as well as for the closed loop flow stabilization The internal suction pump in combination with the flow sensors can supply a constant sample flow rate of 5 SLPM up to altitudes of about 3000...

Page 7: ...Width 14 cm Height 19 cm Weight 4 90 kg Environmental Operating Conditions Indoor use only environmental protection IP X0 ordinary equipment Temperature range 10 40 C Relative humidity range non conde...

Page 8: ...VERY CAREFULLY BEFORE OPERATING THE EQUIPMENT 2 1 Equipment identification label 2 2 Safety notes and labels Equipment operation Read this User s manual BEFORE operating the equipment INCORRECT equip...

Page 9: ...lied with the equipment see below Fire and explosion NEVER install the equipment in explosion risk areas and never use the equipment near flammable substances Equipment overheating ALWAYS assure the e...

Page 10: ...n an even surface next to the Aethalometer The maximum distance between AETH HA PUMP and AE33 AE43 should not exceed 1 5 m The equipment is supplied with two meters of black conductive sample line tub...

Page 11: ...with the Booster Pump Connect them as shown in Figure 5 Figure 5 Connect AETH HA PUMP 12 VDC 150 W connector to power supply with External AC DC power supply adapter VES150PS12 Connect AETH HA PUMP C...

Page 12: ...mum lower flow of the HAP Figure 6 Flow range set valve is located on the rear panel NOTE If the valve is fully open the minimum lower flow of the HAP may exceed the maximum flow of the internal AE33...

Page 13: ...SLPM throughout the entire extended operating range Figure 8 Figure 8 By partly closing the flow range set valve the AE33 AE43 can provide a constant sample flow rate of 5 SLPM throughout the entire e...

Page 14: ...regularly We recommend the following schedule for regular maintenance Maintenance activity Maintenance period Cleaning with dry cloth As needed Inspect the sample line tubing M4995 Monthly Inspect Ext...

Page 15: ...ervice Departments through our web sites Service Support www mageescientific com or www aerosol eu Aerosol d o o Kamni ka 39a SI 1000 Ljubljana SLOVENIA EUROPE tel 386 1 4391 700 support aerosol eu ww...

Page 16: ...contents of this manual with their own names trademarks and logos for branding purposes and for the distribution of the Magee Scientific Aethalometer High Altitude Booster Pump The text may not be mo...

Page 17: ...Aethalometer HAP ___________________________________________________________________________________________________________ User s manual Version 1 0 March 2021 17 17...