background image

 U-Link TRx User Guide  

 

 

Ref. 

09-03-V1.0 

    p 

R/W 

S251 

Over the air format  0 

Æ

transparent mode

Æ

 DSNP mode 

1  

R/W S252  CSMA 

mode 

Æ

Disable CSMA mode

Æ

 Enable CSMA mode 

Check if channel is free with RSSI before 
transmitting. Response is “OK” if channel 
is free, and “KO” if channel is busy. 

0 1 

R/W 

S253 

CSMA mode RSSI 
threshold 

S253=-xxxdBm<cr><lf> with xxx 
decimal value. 
The RSSI range is –130dBm to –70dBm 

-70 1 

R/W 

S254 

RF link speed 

Æ

4800 bps

1

Æ

 7680 bps 

Æ

 9600 bps 

 

0 1 

R/W S255  Squelch 

Æ

High ( as low as possible)

Æ

 Medium (about -114dBm) 

Æ

 Low ( -60dBm TBC

 
 

1  

Serial link management 

The serial link configuration is 38400 bits/s, 8 data bits, no parity, 1 stop bit. 

R/W 

S214 

Command time out  Time out duration for detecting the +++ 

pattern, unit in ms. From 3 up to 240ms 

100  

Miscellaneous 

R/W S233  Transmited 

Call 

Sign  

S233=NZI206211 
(FCC ID + product reference) 

NZI206211 1 

R/W 

S234 

Call sign activation  0 

Æ

disabled

Æ

 enabled 

When enabled, transmit to the air the 
FCC ID by using international Morse 
code, with a carrier at 1200Hz for short 
or long. The Morse code data rate shall 
be between 20 and 25 words per minute. 

0 1 

R/W 

S235 

Serial Number 

The serial number is made up of 11 
digits: yyyywwnnn. 
Where : 
yyyy : year 
ww : week in the year 
nnn : number in the week 
 

00000000 

000 

 

R/W 

S236 

Date of the last 
configuration 

8 digits: yyyymmdd 
Where: 
yyyy : year 
mm: month 
dd: day 

00000000  

R/W S237  Owner 

10 

characters 

max 

Blank 

 

 
Note 1: Only specified for US version. It’s mandatory to fix ATS254=2 (datarate = 9600bps) when using the equipment in US. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Electrical Specifications 

Summary of Contents for U-Link TRx

Page 1: ...PRELIMINARY U Link TRx Radio DATA MODEM User Guide ...

Page 2: ...electronic or paper version photocopy without MAGELLAN consent This document is subject to change without notice All trademarks mentioned in this guide are the property of their respective owner MAGELLAN Zac de la FLEURIAYE BP60 433 44474 CARQUEFOU Ref 09 03 V1 0 ...

Page 3: ...t Power supply 2 Serial link wiring 3 RS232 wiring RS422 wiring 3 RF Modes 3 Framing Modes 4 Transparent Mode 4 DSNP Mode 4 Operating modes 5 Command mode 5 Normal mode 5 AT commands 6 General commands 6 Registers description 6 Electrical Specifications 7 About this document This guide describes the U Link TRx devices their options and accessories ...

Page 4: ...a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY MAGELLAN COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT RF Exposure Warning During operation the user may keep a minimum separation distance of 1 meter with the RF devices Overview The modem is the new MAGELL...

Page 5: ...th different output power 0 5W 2W and 4W The UHF transmitter is controlled and monitored by the connected GNSS unit through remote control commands A UHF relay with receive and transmit functions This transceiver is able to receive GNSS differential message from a base and re broadcast these data at the same frequency in order to increase the range of the radio link between a GNSS base and a rover...

Page 6: ...scribed below Transparent Mode In transparent mode data transmitted on serial link are rough data without frame coding DSNP Mode Data sent to the serial link must be the following Type Content Length Synchronization block Start of text ASCII Character STX 1 char Type of message C P R T X char 1 char Address Station number in BCD 1 char Length of message Length of the message 1 or 2 char s Cadence ...

Page 7: ...onfiguration registers using AT command In command mode the UHF receiver or transmitter is inhibited Rx and Tx excepted when using test command Entering command mode issues on the serial link a sequence The sequence of three consecutive characters is accepted only if no character have been sent before and after the sequence Register S214 defines the silence duration Exiting command mode return int...

Page 8: ... that S235 is not restored by ATR Test modes ATT1 Pure carrier transmission using current channel The output of this mode is achieved by reception of any character on the serial link ATT2 Modulation using current channel Modulation 55 hex data The output of this mode is achieved by reception of any character on the serial link ATT3 Modulation using current channel Modulation with 512 bits pseudo r...

Page 9: ... Command time out Time out duration for detecting the pattern unit in ms From 3 up to 240ms 100 Miscellaneous R W S233 Transmited Call Sign S233 NZI206211 FCC ID product reference NZI206211 1 R W S234 Call sign activation 0 Æ disabled 1 Æ enabled When enabled transmit to the air the FCC ID by using international Morse code with a carrier at 1200Hz for short or long The Morse code data rate shall b...

Page 10: ... 5 modulation with raw data throughput of 9600 bits s Transmitter output power The RF output power on 50ohms load is software selectable between 0 5W 27dBm 2W 33dBm and 4W 36dBm Receiver RF sensitivity The digital sensitivity is typically 110 dBm at 10 5 BER RF Connector The RF connector is a 50 ohms standard TNC female connector Antenna The product will be used with the PROCOM ANTENNA FSP70 460 F...

Reviews: