Basic operation
Resilience D Installation guide. © 2016, all rights reserved
P a g e
|
25
Low salinity indication
Below 3000 ppm – the low salinity bar and the saltshaker icon are
turned on.
Below 2000 ppm – the low salinity bar and saltshaker icons blink.
In all low salinity situations and alarms the unit continues its
operation. If the salinity is too low the requested value on the output
% bar blinks and the maximum achievable output value is visible.
The chlorinator cell should be tested as lime-scale build up on its
blades may affect the low salinity readings. Clean the blades if
necessary.
In case of low salinity indication, the pool water should be tested by
a pool professional and if the salinity is lower than 3000 ppm it is
recommended to add salt according to the table on page 19.
Turbo setting
Pressing the Turbo button starts turbo operation. The unit goes to 100%
output for the adjusted time interval; the Turbo icon starts flashing.
The default turbo setting is 12 hours. To increase the turbo setting in 12
hour intervals, press the Turbo button one/two more times just after
the first press. Then you may set the turbo time for 24, 36, 48, 60 or 72
hours.
The unit starts a Turbo time counter. The turbo counter is displayed on
the numerical display.
Pressing or allows extending or shortening the Turbo time in
intervals of
minute
s.
Minimum 0 and Maximum 72 hours values are accessible (use the same
method of short and long pushes on the and buttons).
Cancelling Turbo Setting –
To cancel the adjusted Turbo setting you may do one of the following actions:
1.
Wait for 5 seconds and press the Turbo button again. Verify that the Turbo icon stops blinking.
2.
Turn the unit ON and OFF using the ON/OFF button.
3.
During the first 5 seconds of Turbo adjusting procedure, press the Turbo button several times until the
countdown display goes from 72 hours to 00:00.