MAGENTA MULTIVIEW™ SERIES
14
12
Appendix B. Setting Sync Signal
Output Termination
In some cases, it may be necessary to disable the 75-ohm termination of the video
outputs on the MultiView™ units. This can be done by opening the case of each unit
and installing jumpers on the circuit board. The settings disable/enable the 75-ohm
termination on individual units. For instance, changing a transmitter termination affects
the local monitor port only; it doesn’t affect the receivers. Conversely, changing a
receiver affects the output port of the receiver, not the transmitter. The following
diagrams show the jumper locations for each type of assembly.
75-ohm sync termination:
To enable: Both jumpers OUT
To disable: Both jumpers IN
Summary of Contents for MultiView AK500 C7