MAGENTA MULTIVIEW™ SERIES
6
3. Setup and Installation
3.1 Data Mode Configuration (SA/SAP versions)
SA series offer RS232 serial and stereo audio. The serial signal is 3 wire TX, RX and
does not support full modem signals. Baud rates for the SA series are defaulted at
9600. Simplex modes are supported without jumper or other changes by simply using
the TX signal only. SA units require no configuration.
SAP series offer pollable RS232 serial in addition to stereo audio. The serial signal is 3
wire TX, RX and does not support full modem signals. Baud rates for the SAP series
are defaulted at 9600. Simplex modes are supported without jumper or other changes
by simply using the TX signal only. See Appendix E on configuration and using SAP
Series.
3.2 Cabling Considerations
• We recommend mounting and connecting all cabling to the Magenta MultiView™
Series components before applying power.
• Makes sure that the CAT7 cable you intend to use has been tested to comply
with the TIA/EIA 568B wiring specification (See
Appendix A
).
3.3 Making the Connections
3.3.1 CONNECTIONS AND SETUP IN GENERAL
This section contains figures showing connections with the specific Magenta MultiView
Series models. In general, however, the connection and setup procedure at both
transmitter and receiver ends is as follows:
NOTE: all units must be the same type for all supported features to function correctly.
For example, an XRTx set for R/L summed audio must be connected to an AK500 C7
set for R/L summed audio. Similarly, a XRTx SA cannot be used with an AK500 C7.
Video modes may function normally, but 4th pair options will not.
At the transmitter end (refer to the transmitter user guide) :
1. Connect the source video to the Magenta MultiView Series transmitter video input
port, which is an HD15 connector labeled SOURCE IN or VIDEO IN.
2. If desired, attach a local monitor via the local monitor port to LOCAL OUT
3. Make your audio and/or serial connections via the phoenix connector or DB9
connector as appropriate.
4
Summary of Contents for MultiView AK500 C7
Page 15: ...15 13 NOTES...
Page 20: ...MAGENTA MULTIVIEW SERIES 20 18 Appendix F Pollable Serial Mode Address Chart...
Page 21: ...21 APPENDIX F Pollable Serial Mode 19 Appendix F Pollable Serial Mode Address Chart cont...
Page 22: ...MAGENTA MULTIVIEW SERIES 22 20 NOTES...
Page 23: ...23 21 NOTES...