Page 62
the machine
To avoid misfunctionings and fire risk You are recommended to carry-out a daily cleaning of the machine com-
ponents by using compressed air.
Do not use abrasive products such as: petrol or solvent, as they would eventually damage painting,
cable boots etc.
Before carrying out any maintenance operation You have to make sure that the power plug is discon-
nected and the machine is stopped.
6.1.4 Check-up
The following components are to be maintained periodically:
−
Safe devices
−
Sensors
−
Microswitches
−
Emergency buttons
6.1.5 Condensate removal from pneumatic system
The condensate level must not exceed the max.value indicated on the air
drum. The exceeding condensate can be removed and conveied into a
6/4 diameter flexible pipe with direct connection to a drain cock.
6.1.6 Check and regulation of the air pressure
Upgrade working-pressure by turning the regulating knob clockwise.Use
lubricating grease of the following kinds: FD22 and HG 32. Verify that the
rate of the air flow is not lower than the indicated minimum working rate.
Set the oil injection by turning the corresponding knob, so that a drop of
oil is injected every 300-600 air litres. After having pressurized the pneu-
matic plant, oil can be added in through the corresponding filling hole:
make sure that the maximum oil level is not exceeded. To open the ntake
valve press and turn the corresponding knob clock-wise. To close the
valve and remove the condensate just turn the corresponding knob coun-
ter-clockwise.
CAUTION
CAUTION
DAILY
EVERY 40 HOURS USE
CAUTION